A young alcoholic presented with severe bilateral bronchopneumonia, which required prolonged treatment with intermittent positive pressure ventilation. High airway pressures were necessary for effective gas exchange. A recurrent tension pneumothorax led to a persistent bronchopleural fistula which resulted in hypercarbia and hypoxaemia despite the use of large minute volumes. Surgical resection was not considered feasible because of extensive local infection. Asynchronous independent lung ventilation was instituted, using a double-lumen endobronchial tube. A considerable leak still occurred through the bronchopleural fistula, and it was only when high frequency jet ventilation was substituted to the fistula-containing lung that the leak was virtually abolished, while improving gas exchange. High frequency jet ventilation in bronchopleural fistula is of potential benefit.
Article PDF
Similar content being viewed by others
References
Carlon GC, Miodownik S, Ray C, Kahn RC (1981) Technical aspects and clinical implications of high frequency jet ventilation with a solenoid valve. Crit Care Med 9:47
Dennis JW, Eigen H, Ballantine TVN, Grosfield JL (1980) The relationship between peak inspiratory pressure and positive end expiratory pressure on the volume of air lost through a bronchopleural fistula. J Pediatr Surg 15(6):971
Dodds CP, Hillman KM (1982) Management of massive air leak with asynchronous independent lung ventilation. Intensive Care Med 8:287
Powner DJ, Grenvik A (1981) Ventilatory management of lifethreatening bronchopleural fistulae. Crit Care Med 9:54
Williams NS, Lewis CT (1976) Bronchopleural fistula: a review of 86 cases. Br. J Surg 520–522