Abstract
We report an accidental overdosage of morphine and midazolam in a patient with renal failure receiving haemofiltration detected by the absence of oesophageal motility. This situation demonstrates the difficulties of assessing the level of sedation as well as the dosage requirements in this type of patient.
Similar content being viewed by others
References
Ball M, Moore RA, Fisher A, McQuay HT, Allen MC, Sear JW (1985) Renal failure and the use of morphine in intensive care. Lancet 1:784
Byatt CM, Lewis LD, Dawling S, Cochrane GM (1984) Accumulation of midazolam after repeated dosage in patients receiving mechanical ventilation in an intensive care unit. Br Med J 289:799
Evans JM, Davies WL, Wise C (1984) Lower oesophageal contractility: a new monitor of anaesthesia. Lancet 2:1151
Osborne RJ, Joel SP, Slevin ML (1986) Morphine intoxication in renal failure: the role of morphine-6-glucoronide. Br Med J 292:1548
Shimomura K, Kamata O, Ueki S, Ida S, Oguri K (1971) Analgesic effect of morphine glucuronides. Tohuku J Exp Med 105:45
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Sinclair, M.E., Suter, P.M. Detection of overdosage of sedation in a patient with renal failure by the absence of lower oesophageal motility. Intensive Care Med 14, 69–71 (1988). https://doi.org/10.1007/BF00254126
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00254126