Reliability of measurement of oxygen uptake by a portable telemetric system

  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Summary

The purpose of the present study was to check the reliability of measurements of oxygen uptake (VO2) using a newly developed portable telemetry system. This system (K2) consisted of a face mask, a flow meter, a gas analyser with a transmitter, and a receiver. The total mass for the subject to carry was about 850 g. Three experiments were carried out, firstly to check the reliability and reproducibility of the flow meter and the K2 gas analyser, secondly to check the accuracy of K2 by comparing it with the Douglas bag method (DB), and thirdly to apply K2 to sports activities. In the first experiment, the flow meter was highly accurate up to 180 l·min−1 with good reproducibility. The measurement error of the gas analyser was less than 2%. In the second experiment, there was no significant difference in the calculated ventilation between K2 and DB. The VO2 showed no significant difference between K2 and DB with some exceptions. In the third experiment, we succeeded in the measurement of VO2 during rowing on water. The measurement of VO2 during running and playing soccer was also possible. It would seem that the present system could well be a powerful tool in the field measurement of VO2 during various sports activities.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ballal MA, MacDonald IA (1982) An evaluation of the Oxylog as a portable device with which to measure oxygen consumption. Clin Phys Physiol Meas 3:57–65

    Google Scholar 

  • Dal Monte A, Faina M, Leonard LM, Todara A, Guidi G, Petrelli G (1989) Maximum oxygen consumption by telemetry. Scuola Dello Sport. CONI [Anno VIII] 15:35–44

    Google Scholar 

  • Dill DB (1966) Assessment of work performance. J Sports Med 6:3–8

    Google Scholar 

  • Di Prampero PE, Cortili G, Celentano F, Cerretelli P (1971) Physiological aspects of rowing. J Appl Physiol 31:853–857

    Google Scholar 

  • Fukunaga T, Matsuo A, Yamamoto K, Asami T (1986) Mechanical efficiency in rowing. Eur J Appl Physiol 55:471–475

    Google Scholar 

  • Hagerman FC, Connors MC, Gault JA, Hagerman GR, Polinski WJ (1978) Energy expenditure during simulated rowing. J Appl Physiol 45:87–93

    Google Scholar 

  • Ikegami Y, Hiruta S, Ikegami H, Miyamura M (1988) Development of a telemetry system for measuring oxygen uptake during sports activities. Eur J Appl Physiol 57:622–626

    Google Scholar 

  • Mahler D, Andrea BE, Ward JL (1987) Comparison of exercise performance on rowing and cycle ergometers. Res Q 58:41–46

    Google Scholar 

  • Riley JL (1972) Transmitter for recording respiration rate information by radiotelemetry. J Appl Physiol 32:259–260

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kawakami, Y., Nozaki, D., Matsuo, A. et al. Reliability of measurement of oxygen uptake by a portable telemetric system. Europ. J. Appl. Physiol. 65, 409–414 (1992). https://doi.org/10.1007/BF00243506

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00243506

Key words

Navigation