Skip to main content
Log in

Nonionic monomers and dimers

  • Contrast Media
  • Review Article
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

The 10-year-long debate regarding high-osmolar ionic vs low-osmolar nonionic contrast media has ceased. Now we are confronted with at least eight nonionic monomers and two nonionic dimers. Do these ten contrast agents differ from each other? The manufacturers say yes, but in clinical practice differences have, with a few exceptions, turned out to be very marginal and by no means to the extent which was found between high- and low-osmolar contrast media. Only time will tell whether there are any major differences of clinical importance between the “old” and the new nonionic agents.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Thomsen HS (1994) Universal use of low-osmolar contrast media: a European perspective. Acad Radiol 1: 295

    Google Scholar 

  2. Dawson P (1995) Design plays major role in new contrast media. Diagn Imaging Eur June: 3

  3. Almén T (1994) The etiology of contrast medium reactions. Invest Radiol 29: S37

    Google Scholar 

  4. Moreau JF (1995) Le retrait du Télébrix 38 ou la mémoire de l'iode. J Radiol 76: 9

    Google Scholar 

  5. Caille J-M, Leonardi M, Holland I (1995) Contrast selection key to safety of CNS imaging. Diagn Imaging Eur June: 15

  6. Sovak M (1985) Introduction: state of the art and design principles of contrast media. In: Sovak M (ed) Handbook of experimental pharmacology, vol 73. Springer, Heidelberg Berlin New York, p 1

    Google Scholar 

  7. Thomsen HS, Dorph S, Mygind T, Sovak M, Nielsen H, Rygaard H, Larsen S, Skaarup P, Hemmingsen L, Holm J (1988) Intravenous injection of ioxilan, iohexol and diatrizoate. Effects on urine profiles in the rat. Acta Radiol 29: 131

    Google Scholar 

  8. Morris TW (1993) The physiologic effects of nonionic contrast media on the heart. Invest Radiol 28: S45

    Google Scholar 

  9. Krause W (1994) Preclinical characterization of iopromide. Invest Radiol 29: S21

    Google Scholar 

  10. Rosati G, Davies A, Spinazzi A (1995) Predictable and unpredictable adverse reactions to iomeprol and iopromide. Acad Radiol 3: (in press)

  11. Haughton VM, Papke A, Hyland D, Drayer BP, Osborn AG, Maravilla K, Hilal SK (1994) Safety and efficacy of iopromide in cerebral arteriography. Invest Radiol 29: S94

    Google Scholar 

  12. Dawson P (1994) Contrast agents in interventional radiology. Adv X-ray Contrast 2: 18

    Google Scholar 

  13. Bien S (1995) A non-ionic dimeric contrast agent in cerebral angiography. Eur Radiol 5 (Suppl 2): 45

    Google Scholar 

  14. Fischbach R, Landwehr P, Nossen JO, Berg KJ, Eichhorn G, Heindel W, Jacobsen TF (1994) Iodixanol and iopamidol in intravenous DSA. A comparative phase III trial. Cardiovasc Intervent Radiol 17 (Suppl 2): S124

    Google Scholar 

  15. Flinck A, Selin K, Bjorneld L (1994) Iodixanol in cardioangiography. Acta Radiol 35 (Suppl 394): S39

    Google Scholar 

  16. Gmeinwieser JK, Wenzel-Hora BI (1995) Peripheral and penile angiography with iotrolan 280 versus non-ionic monomers: results of the European clinical phase II and III trials. Eur Radiol 5 (Suppl 2): 30

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Correspondence to: H. S. Thomsen

Rights and permissions

Reprints and permissions

About this article

Cite this article

Stacul, F., Thomsen, H.S. Nonionic monomers and dimers. Eur. Radiol. 6, 756–761 (1996). https://doi.org/10.1007/BF00187685

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00187685

Key words

Navigation