References
Wahner HW, Dunn WL, Brown ML, Morin RL, Riggs BL. Comparison of dual-energy X-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine. Mayo Clin Proc 1988; 63:1075–1084.
Kelly TL, Slovik DM, Schoenfeld DA, Neer RM. Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine. J Clin Endocrinol Metab 1988; 67:839–844.
Cullum ID, Ell PJ, Ryder JP. X-ray dual photon absorptiometry: a new method for the measurement of bone density. Br J Radiol 1989; 62:587–592.
Sorenson JA, Duke PR, Smith SW. Simulations studies of dual-energy X-ray absorptiometry. Med Phys 1989; 16:75–80.
Blake GM, Tong CM, Fogelman I. Intersite comparison of the Hologic QDR-1000 dual energy X-ray bone densitometer. Br J Radiol 1991 ; 440–446.
Blake GM, McKeeney DB, Chhaya SC, Ryan PJ, Fogelman I. Dual energy x-ray absorptiometry: the effects of beam hardening on bone density measurements. Med Phys 1992; 19:459–465.
Mazess R, Collick B, Trempe J, Barden H, Hanson J. Performance evaluation of a dual-energy X-ray bone densitometer. Calcif Tissue Int 1989; 44:228–232.
Buxton FMA, Blake GM, Parker JC, Fogelman I. Spinal bone density measured with a 5 second scan. Br J Radiol 1993; 66:275–277.
Steiger P, van Stetten E, Weiss H, Stein JA. Paired AP and lateral supine dual x-ray absorptiometry of the spine: initial results with a 32 detector system. Osteoporosis Int 1991; 1:190 (abstract).
Pommet R, Chambellan D, Reverchon P, Pare C, Lecluse A, Panissier P. Array multidetector bone densitometer for supine lateral vertebral measurement in lateral projection. Osteoporosis Int 1991; 1:190 (abstract).
Devogelaer JP, Baudoux C, Nagant de Deuxchaisnes C. Reproducibility of BMD measurements on the Hologic QDR-2000. Calcif Tissue Int 1993; 52:164 (abstract).
Lewis MK, Blake GM, Fogelman I. Patient dosimetry studies on the Hologic QDR-1000, QDR-1000/W and QDR-2000. Calcif Tissue Int 1993; 52:164 (abstract).
Lehmann R, Wapniarz M, Kvasnicka HM, Baedeker S, Klein K, Allolio B. Reproduzierbarkeit van Knochendichtemessungen am distalen Radius mit einem hochauflösenden Spezial scanner für periphere quantitative Computertomographie (single energy pQCT). Radiologe 1992; 32:177–181.
Schneider P, Berner W, Rendl J, Eilles C, Schlisske K, Scheubeck M. Stellenwert zweier unterschiedlicher Knochendichtemessmethoden zur Bestimmung des Mineralgehalts am peripheren und axialen Skelett. Z Orthop 1992; 130:16–21.
Langton C, Palmer SB, Porter RW. Measurement of broad-band ultrasonic attenuation in cancellous bone. Eng Med 1984; 13:89–91.
Miller CG, Herd RIM, Ramalingam T, Fogelman I, Blake GM. Ultrasonic velocity measurements through the calcaneus: which velocity should be measured? Osteoporosis Int 1993; 3:31–35.
Porter RW, Miller CG, Graiinger D, Palmer SB. Prediction of hip fracture in elderly women: a prospective study. Br Med J 1990;301:638–641.
Ryan PJ, Blake GM, Fogelman I. Measurement of forearm bone mineral density in normal women by dual energy X-ray absorptiometry. Br J Radiol 1992; 65:127–131.
Stetten EC van, Berger N, Kelly TL, Stein JA. New applications of X-ray absorptiometry. Osteoporosis Int 1991; 1:191 (abstract).
Richmond BJ, Eberle RW, Stulberg BN, Deal CL. DEXA measurement of peri-prosthetic bone mineral density in total hip arthroplasty. Osteoporosis Int 1991; 1:191 (abstract).
Trevisan C, Cherubini R, Ulivieri FM, Gondolini GG, Randelli G, Ortolani S. Dual energy X-ray absorptiometry in the evaluation of periprosthetic bone mineral status: analysis protocols and reproducibility. Osteoporosis Int 1991; 1:191 (abstract).
Herd RJM, Blake GM, Parker JC, Ryan PJ, Fogelman I. Total body studies in normal British women using dual x-ray absorptiometry. Br J Radiol 1993; 66:303–308.
Kohrt W, Snead D, Rupich R, Birge S. Bone and soft tissue assessment with the QDR-1000/W. Osteoporosis Int 1991; 1:199 (abstract).
Wilson CR, Fogelman I. Lateral lumbar BMD with dual energy absorptiometry. In: Ring EFJ, ed. Current research in osteoporosis and bone mineral measurement. London: British Institute of Radiology 1990; 15–17 (abstract).
Slosman DO, Rizzoli R, Donath A, Bonjour J-Ph. Vertebral bone mineral density measured laterally by dual energy x-ray absorptiometry. Osteoporosis Int 1990; 1:23–29.
Uebelhart D, Duboeuf F, Meunier PJ, Delmas PD. Lateral dual photon absorptiometry: a new technique to measure the bone mineral density at the lumbar spine. J Bone Miner Res 1990;5:525–531.
Devogelaer JP, Baudoux C, Nagant de Deuxchaisnes C. Lack of precision of the lumbar BMD measurements with the QDR-1000/W when the patients are lying in a lateral position. Calcif Tissue Int 1993; 52:163 (abstract).
Lilley J, Eyre S, Heath DA. In vivo and in vitro precision for BMD of the spine measured laterally using DEXA. In: Ring EFJ, ed. Current research in osteoporosis and bone mineral measurement II: 1992. London: British Institute of Radiology; 1992; 27–28 (abstract).
Herd RJM, Blake GM, Parker JC, Ryan PJ, Fogelman I. Supine lateral is superior to decubitus lateral for dual x-ray absorptiometry studies of the lumbar spine. Nucl Med Commun 1993; 14:277 (abstract).
Kelly TL, Pomeroy M, Richardson TL, Stein JA. New developments in x-ray densitometry. In: Ring EFJ, ed. Current research in osteoporosis and bone mineral measurement. London: British Institute of Radiology 1990; 19–20 (abstract).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Blake, G.M., Fogelman, I. Recent advances in bone densitometry. Eur J Nucl Med 20, 735–737 (1993). https://doi.org/10.1007/BF00180901
Issue Date:
DOI: https://doi.org/10.1007/BF00180901