Abstract

When using a nylon thread for the attachment of a pseudophakos to the iris, it may happen that the suture is slung tightly around the implant-lens. In such a case this constitutes a clinical experiment where in one and the same eye one part of the nylon thread is in its normal state (the cut-off ends) and the rest is in a stretched state, both under the same environmental conditions and for the same length of time. The differences in structure of the two parts of the nylon thread are thus fully comparable.

Clinical observations show that when the nylon thread is under tension it will be eroded by chemical influences. It does not make any difference whether the nylon is used for corneal, scleral or intra-ocular suturing. The duration of the observations is still too short to predict the behaviour of nylon thread which is not stretched.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Doden, W. & H. Schmitt. Veränderungen an Kunststoff-Fäden nach langer Verweildauer im Hornhautgewebe. Klin. Mbl. Augenheilk. 164: 155–159 (1974).

    Google Scholar 

  • Doden, W. & H. Schmitt. Mikroskopische Befunde an unbenutzten bestrahlten und unbestrahlten Kunststoff-Fäden. Klin. Mbl. Augenheilk. 167: 291–294 (1975).

    Google Scholar 

  • Harnisch, J.P. & G. Löschau. Rasterelektronenmikroskopische Untersuchungen an Kunststoff-Fäden. Klin. Mbl. Augenheilk. 166: 131–136 (1975).

    Google Scholar 

  • Nordlohne, M.E. The intra-ocular implant lens. Thesis. Junk, The Hague (1975).

    Google Scholar 

  • Partridge, J., A. Rich, W. Dunlap & S.D. McPherson Jr. Ocular tissue fluids and nylon, virgin silk, and collagen sutures. Arch. Ophthal. 90: 271–273 (1973).

    Google Scholar 

  • Schmitt, H. & W. Doden. Mikroskopische und bakteriologische Untersuchungen an Kunststoff-Fäden nach längerer Verweildauer im Hornhautgewebe. Klin. Mbl. Augenheilk. 161: 654–658 (1972).

    Google Scholar 

  • Schwertassek, K. & J. Dvorak. Beitrag zum Studium des Abbaues von Synthesefaserstoffen im lebenden Organismus. Faserforschung und Textiltechnik 21: 78–83 (1970).

    Google Scholar 

  • Worst, J.G.F. Iris sutures for artificial lens fixation-perlon vs. stainless steel. Trans. Amer. Ophthal. Otolaryng. 81: OP.102–104 (1976).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Blanksma, L.J., Siertsema, J.V. Changes in the structure of intra-ocular nylon. Doc Ophthalmol 44, 223–229 (1977). https://doi.org/10.1007/BF00171477

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00171477

Keywords

Navigation