Abstract
We have developed a new set of tests for evaluation of visual function through media opacities, based on vernier acuity measurements (hyperacuity). In this paper, results of one of these tests, the ‘gap test’, are compared in patients with posterior subcapsular (PSC) cataract versus nuclear cataract (NC). Patients with PSC cataract often report multiple images or significant ‘star burst’ effects. We hypothesized the presence of ‘multi-prismatic’ and/or high frequency spurious resolution phenomena due to PSC cataract characteristic substructure. We were able to minimize these effects by using 1) a pinhole held close to the eye, 2) a large (adapting) background field of white light superimposed on the vernier test targets, 3) a low-pass spatial filter applied to the targets. When the particular problems associated with PSC cataract are not present or are adequately addressed and when patients are matched for visual acuity, the hyperacuity ‘gap test’ shows less functional effect due to the opacity for PSC cataract than NC in all the cases we have tested. These findings, moreover, indicate that visual acuity provides an insufficient description of the effects of intraocular scattering on image formation. The results emphasize the importance and the necessity of developing models that better clarify the specific effects of different types of ocular media opacities.
Similar content being viewed by others
References
Bettelheim FA: Physical basis of lens transparency. In: Maisel H (ed) The ocular lens (structure, function, and pathology). Marcel Dekker Inc, New York-Basel, 1985, pp 265–300.
Enoch JM, Williams RA, Essock EA, Barricks M: Hyper-acuity perimetry: Assessment of macular function through ocular opacities. Arch Ophthalmol 102: 1164–1168, 1984.
Enoch JM, Williams RA, Essock EA, Fendick M: Hyper-acuity: A promising means of evaluating vision through cataract. In: Osborne NN, Chader GJ (eds) Progress in retinal research. Pergamon Press, Oxford, Vol. 4, 1985, pp 67–88.
Enoch JM, Baraldi P, Knowles R: New techniques in clinical application of hyperacuity tests on patients with media opacities. Invest Ophthalmol Vis Sci (Suppl), 1986, in press.
Essock EA, Williams RA, Enoch JM, Raphael S: The effects of image degradation by cataract on vernier acuity. Invest Ophthalmol Vis Sci 25: 1043–1050, 1984.
Essock EA, Enoch JM, Williams RA, Barricks M, Raphael S: Joint application of hyperacuity perimetry and gap tests to assess visual function behind cataracts: initial trials. Doc Ophthalmol 60: 293–312, 1985.
Faye EE: Low vision aids. In: Safir A (ed) Refraction and clinical optics. Harper & Row Publisher, Hagerstown, 1984, pp 215–228.
Hess R, Garner LF: The effects of corneal edema on visual function. Invest Ophthalmol Vis Sci 16: 5–13, 1978.
Hess R, Woo G: Vision through cataracts. Invest Ophthalmol Vis Sci 17: 428–435, 1978.
Hirsch RP, Nadler MP, Miller D: Clinical performance of a disability glare tester. Arch Ophthalmol 102: 1633–1636, 1984.
Tripathy RC, Tripathy BC: Lens morphology, aging and cataract. J. Gerontol 38: 258–270, 1983.
Westheimer G: The spatial sense of the eye. Invest Ophthalmol Vis Sci 18: 893–912, 1979.
Williams RA, Enoch JM, Essock EA: The resistance of selected hyperacuity configurations to image degradations. Invest Ophthalmol Vis Sci 25: 389–399, 1984.
Author information
Authors and Affiliations
Additional information
P. Baraldi is on leave from Clinica Oculistica, Universita' di Modena, Policlinico, Italy.
Rights and permissions
About this article
Cite this article
Baraldi, P., Enoch, J.M. & Raphael, S. Vision through nuclear and posterior subcapsular cataract. Int Ophthalmol 9, 173–178 (1986). https://doi.org/10.1007/BF00159846
Issue Date:
DOI: https://doi.org/10.1007/BF00159846