Skip to main content
Log in

Contact glasses for use with high power lasers

Two new contact glasses for microsurgery at the iris, in the pupillary and the retropupillary space

  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

Two new contact glasses, one for irradiation of the iris and the other for irradiation of pathological structures within the pupillary and retropupillary regions are described. First order geometric considerations using the Young-Weierstrass imaging theorem indicate nearly aberration-free, stigmatic focussing, even for large numerical apertures. For surgical tasks utilizing high-power lasers, excellent focussing of strongly convergent ray-bundles which lead to small focus diameter and large diameters while passing through the pre-focal optical media are seen to be essential. Thus the efficiency of the laser-surgical treatment, its reliability, as well as security and harmlessness within the pre-focal media are increased.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Abraham, R.K. Protocol for single session argon laser iridectomy for angle closure glaucoma. Int. Ophthalmol. Clin. 21: 145–165 (1981).

    Google Scholar 

  2. Bayadi, G.E. New method of slit lamp microophthalmoscopy. Br. J. Ophthal. 37: 625–628 (1953).

    Google Scholar 

  3. Comberg, D. La photocoagulation avec un verre de contact à miroir. Bull. Soc. Fr. Ophtalmol. 77: 545–547 (1964).

    Google Scholar 

  4. Goldmann, H. Les techniques générales d'examen. In: Biomicroscopie du corps vitré et du fond de l'oeil. Edit. Masson & Cie, Paris, pp. 15–27 (1957).

    Google Scholar 

  5. Hruby, K. Spaltlampen-Mikroskopie. Urban und Schwarzenberg, Wien (1950).

    Google Scholar 

  6. Koeppe, L. Mikroskopie des lebenden Auges II. Springer-Verlag, Berlin (1922).

    Google Scholar 

  7. Le Grand, Y. Optique physiologique I. La dioptrique de l'oeil et sa correction. Edit. Rev. Opt., Paris, pp. 49–54 (1952).

  8. Lörtscher, H.P. Investigation of laser induced breakdown for ophthalmological applications. In: Neodymium YAG lasers: Short pulse ophthalmic surgical lasers. Edit. S. Trokel. Publ., Appleton-Century-Crofts, New York (1982).

    Google Scholar 

  9. Ridley, F. The contact lens in investigation and treatment. Trans. Ophthalmol. Soc. U.K. 74: 377–410 (1954).

    Google Scholar 

  10. Riedel, H. Photography. In: Glaucoma. Conceptions of a Disease. Edit. K. Heilmann & T. Richardson. Georg Thieme Publ., Stuttgart, pp. 243–260 (1978).

    Google Scholar 

  11. Roussel, Ph. & F. Fankhauser. Contact glass for use with high power lasers - geometrical and optical aspects. Int. Ophthalmol. 3: 000-000 (0000).

    Google Scholar 

  12. Schirmer, K.E. Argon-Iridektomie und Gonioplastik in der Behandlung des Engwinkelglaukoms. Klin. Monatsbl. Augenheilk. 181: 132–134 (1982).

    Google Scholar 

  13. Schlegel, H.J. Das Panfundoskop in Diagnostik und Therapie peripherer Netzhauterkrankungen. In: Ber. dtsch. Ophthal. Ges. J.F. Bergmann-Verlag, München, pp. 75–78 (1977).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Riquin, D., Fankhauser, F. & Lörtscher, H. Contact glasses for use with high power lasers. Int Ophthalmol 6, 191–200 (1983). https://doi.org/10.1007/BF00141128

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00141128

Keywords

Navigation