Abstract
Two new contact glasses, one for irradiation of the iris and the other for irradiation of pathological structures within the pupillary and retropupillary regions are described. First order geometric considerations using the Young-Weierstrass imaging theorem indicate nearly aberration-free, stigmatic focussing, even for large numerical apertures. For surgical tasks utilizing high-power lasers, excellent focussing of strongly convergent ray-bundles which lead to small focus diameter and large diameters while passing through the pre-focal optical media are seen to be essential. Thus the efficiency of the laser-surgical treatment, its reliability, as well as security and harmlessness within the pre-focal media are increased.
Similar content being viewed by others
References
Abraham, R.K. Protocol for single session argon laser iridectomy for angle closure glaucoma. Int. Ophthalmol. Clin. 21: 145–165 (1981).
Bayadi, G.E. New method of slit lamp microophthalmoscopy. Br. J. Ophthal. 37: 625–628 (1953).
Comberg, D. La photocoagulation avec un verre de contact à miroir. Bull. Soc. Fr. Ophtalmol. 77: 545–547 (1964).
Goldmann, H. Les techniques générales d'examen. In: Biomicroscopie du corps vitré et du fond de l'oeil. Edit. Masson & Cie, Paris, pp. 15–27 (1957).
Hruby, K. Spaltlampen-Mikroskopie. Urban und Schwarzenberg, Wien (1950).
Koeppe, L. Mikroskopie des lebenden Auges II. Springer-Verlag, Berlin (1922).
Le Grand, Y. Optique physiologique I. La dioptrique de l'oeil et sa correction. Edit. Rev. Opt., Paris, pp. 49–54 (1952).
Lörtscher, H.P. Investigation of laser induced breakdown for ophthalmological applications. In: Neodymium YAG lasers: Short pulse ophthalmic surgical lasers. Edit. S. Trokel. Publ., Appleton-Century-Crofts, New York (1982).
Ridley, F. The contact lens in investigation and treatment. Trans. Ophthalmol. Soc. U.K. 74: 377–410 (1954).
Riedel, H. Photography. In: Glaucoma. Conceptions of a Disease. Edit. K. Heilmann & T. Richardson. Georg Thieme Publ., Stuttgart, pp. 243–260 (1978).
Roussel, Ph. & F. Fankhauser. Contact glass for use with high power lasers - geometrical and optical aspects. Int. Ophthalmol. 3: 000-000 (0000).
Schirmer, K.E. Argon-Iridektomie und Gonioplastik in der Behandlung des Engwinkelglaukoms. Klin. Monatsbl. Augenheilk. 181: 132–134 (1982).
Schlegel, H.J. Das Panfundoskop in Diagnostik und Therapie peripherer Netzhauterkrankungen. In: Ber. dtsch. Ophthal. Ges. J.F. Bergmann-Verlag, München, pp. 75–78 (1977).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Riquin, D., Fankhauser, F. & Lörtscher, H. Contact glasses for use with high power lasers. Int Ophthalmol 6, 191–200 (1983). https://doi.org/10.1007/BF00141128
Issue Date:
DOI: https://doi.org/10.1007/BF00141128