Skip to main content
Log in

Use of fluorosilicone to unfold a giant retinal tear

  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

We unfolded and attached a giant retinal tear with an inverted edge using fluorosilicone oil while the patient was in the supine position. The advantages of high viscosity (10,000 centistokes) and specific gravity (1.31) fluorosilicone are discussed in this paper.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ando F, Kondo J: A plastic tack for the treatment of retinal detachment with giant tear. Am J Ophthalmol 95: 260–261, 1983

    Google Scholar 

  2. Armaly MF: Ocular tolerance to silicones: I. Replacement of aqueous and vitreous by silicone fluids. Arch Ophthalmol 68: 390–395, 1962

    Google Scholar 

  3. Cibis PA, Becher B, Okun E, et al: The use of liquid silicone in retinal detachment surgery. Arch Ophthalmol 68: 590–599, 1962

    Google Scholar 

  4. Cibis PA: Vitreous transfer and silicone injections. Trans Am Acad Ophthalmol Otolaryngol 68: 983–987, 1964

    Google Scholar 

  5. Constable I, Mohamed S, Tan PL: Superviscous silicone liquid in retinal surgery. Aust J Ophthalmol 10(1): 5–11, 1982

    Google Scholar 

  6. Federman JL, Shakin JL, Lanning RC: The microsurgical management of giant retinal tear with trans-scleral retinal sutures. Ophthalmology 89: 832–839, 1982

    Google Scholar 

  7. Fitzgerald CR: The use of Healon in a case of rolled-over retina. Retina 1: 227, 1981

    Google Scholar 

  8. Freeman HM, Couvillion GC, Schepens CL: Intraocular balloon: Clinical application. Arch Ophthalmol 83: 715–721, 1970

    Google Scholar 

  9. Freeman MH, Castillejos ME: Current management of giant retinal breaks, results with vitrectomy and total airfluid exchange in 95 cases. Trans Am Ophthalmol Soc 79: 89–102, 1981

    Google Scholar 

  10. Freeman JL, Jeffry LS, Lanning RC: The microsurgical management of giant retinal tears with trans-scleral retinal sutures. Ophthalmology 89: 832–839, 1982

    Google Scholar 

  11. Fung WE, Donals LH, Cleasby GW: Combined technique for a 355° traumatic giant retinal break. Arch Ophthalmol 93: 264–266, 1975

    Google Scholar 

  12. Hirose T, Schepens CL, Lopanscri C: Subtotal open-sky vitrectomy for severe retinal detachment occurring as a late complication of ocular trauma. Ophthalmology 88: 1–9, 1981

    Google Scholar 

  13. Howard RO, Gaasterland DE: Giant retinal dialysis and tear. Arch Ophthalmol 84: 312–315, 1970

    Google Scholar 

  14. Lean JS, Leaver PK, Cooling RJ. et al: Management of complex retinal detachments by vitrectomy and fluid/silicone exchange. Trans Ophthalmol Soc UK 102: 203–205, 1982

    Google Scholar 

  15. Leaver PK, Cooling RJ, Feretis EB, et al: Vitrectomy and fluid/silicone oil exchange for giant retinal tears: results at six months. Br J Ophthalmol 68: 432–438, 1984

    Google Scholar 

  16. Machemer R, Allen AW: Retinal tears 180° and greater: Management with vitrectomy and intravitreal gas. Arch Ophthalmol 94: 1340–1346, 1976

    Google Scholar 

  17. Norton EWD, Aaberg T, Fung WE, et al: Giant retinal tears: I. Clinical management with intravitreal air. Am J Ophthalmol 68: 1101–1121, 1969

    Google Scholar 

  18. North EWD: Intraocular gas in the management of selected retinal detachment. Trans Am Acad Ophthalmol Otolaryngol 77: 85–98, 1973

    Google Scholar 

  19. Paylor R, Peyman GA, Badri S: Intravitreal fluorosilicone oil after vitrectomy. Unpublished data, 1986

  20. Peyman GA: A new operating table for the management of giant retinal breaks. Arch Ophthalmol 99: 498–499, 1981

    Google Scholar 

  21. Peyman GA, Rednam KR, Seetner AA: Retinal microincarceration with penetrating diathermy in the management of giant retinal tears. Arch Ophthalmol 102: 562–565, 1984

    Google Scholar 

  22. Schepens CL, Freeman HM, Thompson RF: A power driven multipositional operating table. Arch Ophthalmol 73: 671–673, 1965

    Google Scholar 

  23. Schepens CL, Freeman HM: Current management of giant retinal breaks. Trans Am Acad Ophthalmol Otolaryngol 71: 474–487, 1967

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Peyman, G.A., Smith, R.T. Use of fluorosilicone to unfold a giant retinal tear. Int Ophthalmol 10, 149–151 (1987). https://doi.org/10.1007/BF00139340

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00139340

Key words

Navigation