Abstract
This paper focuses to enhance the dynamic behavior of the power system during load disturbances using PID plus double derivative (DD) PIDD controller optimized with water cycle algorithm of weighted-sum multi-objective function. The multi-objective function comprises the characterizations of absolute error multiplied with time over integral (ITAE) and error squared over integral (ISE) performance indices. An analysis is performed to demonstrate the best set of weightage for investigation. Finally, it is confirmed that the performance of the multi-objective-based controlling approach is a way better than other controllers mentioned in the literature.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Tungadio DH, Sun Y (2019) Load frequency controllers considering renewable energy integration in power system. Energy Rep 05:436–454
Sharma Y, Saikia LC (2015) Automatic generation control of a multi-area ST-Thermal power system using Grey wolf optimizer algorithm based classical controllers. Electr Power Energy Syst 73:853–862
Naga Sai Kalyan CH, Sambasiva Rao G (2020) Performance comparison of various energy storage devices in combined LFC and AVR of multi area system with renewable energy integration. Int J Renewable Energy Res 10(02):933–944
Sahu RK, Panda S, Padhan S (2015) A hybrid firefly algorithm and pattern search technique for automatic generation control of multi area power systems. Electr Power Energy Syst 64:9–23
Nosratabadi SM, Bournapour M, Gharaei MA (2019) Grasshopper optimization algorithm for optimal load frequency control considering predictive functional modified PID controller in restructured multi-resource multi-area power system with redox flow battery units. Control Eng Pract 89:204–227
Guha D, Roy PK., Banerjee S (2018) Optimal tuning of 3 degree-of-freedom proportional-integral-derivative controller for hybrid distributed power system using dragon fly algorithm. Comput Electr Eng 72:137–153
Arya Y (2019) A new optimized fuzzy FOPI-FOPD controller for automatic generation control of electric power systems. J Franklin Inst 356:5611–5629
Kaseem AM (2010) Neural predictive controller of a two-area load frequency control for interconnected power system. Ain Shams Eng J 01:49–58
Tasnin W, Saikia LC (2018) Comparative performance of different energy storage devices in AGC of multi-source system including geothermal power plant. J Renewable Sustainable Energy 10:024101
Raju M, Saikia LC, Sinha N (2016) Automatic generation control of a multi-area system using ant lion optimizer algorithm based PID plus second order derivative controller. Electr Power Energy Syst 80:52–63
Naga Sai Kalyan CH, Sambasiva Rao G (2020) Coordinated SMES and TCSC damping controller for load frequency control of multi area power system with diverse sources. Int J Electr Eng Inf 12(04):747–769
Ghaffarzadeh N (2015) Water cycle algorithm based power system stabilizer robust design for power systems. J Electr Eng 66(02):91–96
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this chapter
Cite this chapter
Kalyan, C.N.S., Suresh, C.V., Ramaniah, U. (2022). Multi-objective Weighted-Sum Optimization for Stability of Dual-Area Power System Using Water Cycle Algorithm. In: Gupta, O.H., Sood, V.K., Malik, O.P. (eds) Recent Advances in Power Systems. Lecture Notes in Electrical Engineering, vol 812. Springer, Singapore. https://doi.org/10.1007/978-981-16-6970-5_2
Download citation
DOI: https://doi.org/10.1007/978-981-16-6970-5_2
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-16-6969-9
Online ISBN: 978-981-16-6970-5
eBook Packages: EnergyEnergy (R0)