Study on Non-contact Heart Beat Measurement Method by Using Depth Sensor

  • Conference paper
  • First Online:
World Congress on Medical Physics and Biomedical Engineering 2018

Part of the book series: IFMBE Proceedings ((IFMBE,volume 68/1))

Abstract

For the purpose of simple observation of the mechanical phenomenon of the heart, we propose a new non-contact heartbeat measurement using a depth sensor. The depth sensor is an image sensor applying infrared light projection, and by using this sensor it is possible to calculate the three dimensional shape of the chest. In addition, it is possible to measure minute displacement appearing on the body surface by heartbeat. By visualizing the distribution of shape change using computer graphics, visualization of the heart beat is realized. Since the method is non-contact measurement, it does not prevent simultaneous measurement with the electrocardiogram. Therefore, it can be expected to be used as a means for simultaneously observing mechanical and electric phenomena of the heart. Simultaneous measurement using the method and electrocardiogram was performed. As a result of the measurement of three subjects (two males in 20 s and one male in 40 s), it was confirmed that the peak interval of the waveforms obtained by the two methods shows high consistency. The difference between the two peak intervals was less than 0.04 s. In the measurement, subjects stopped respiration, by applying the filtering process, it is also possible to detect the heartbeat waveform during breathing. During respiration, fluctuations are included in the measured waveform. In the simultaneous measurement of the two methods, the difference in the peak intervals is less than 0.05 s. This value is slightly larger than when breathing is stopped. In addition, as a result of the visualization of heart beat, the phase of vibrations by the heartbeat is different at each position on the chest surface. Specifically, a phase lag occurred upward direction from the abdominal, and it is visible by animation. This result suggests that the observation of the mechanical phenomenon of the heart may be realized by the method.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Aoki, H., et al. “Extraction and Visualization of Cardiac Beat by Grid-Based Active Stereo,” Advances in Depth Images Analysis and Applications, LNCS7854, pp. 147–157, Springer (2013)

    Google Scholar 

  2. Machida, H., et al.: “High Efficiency Fiber Grating for Producing Multiple Beams of Uniform Intensity,” Appl. Opt., 23(2), pp. 330–332 (1984)

    Google Scholar 

  3. AOKI, H, et al.: “Calculation of Ventilation Threshold Using Noncontact Respirometry,” In: Proceedings of 30th IEEE EMBC, pp. 2273–2276 (2008)

    Google Scholar 

Download references

Acknowledgements

This work was supported by JSPS KAKENHI Grant Number JP16K08977.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hirooki Aoki .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Aoki, H., Suzuki, A., Shiga, T. (2019). Study on Non-contact Heart Beat Measurement Method by Using Depth Sensor. In: Lhotska, L., Sukupova, L., Lacković, I., Ibbott, G.S. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/1. Springer, Singapore. https://doi.org/10.1007/978-981-10-9035-6_62

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-9035-6_62

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-9034-9

  • Online ISBN: 978-981-10-9035-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics