Skip to main content

Effect of sinus attenuation in MR-based attenuation correction in 18F-FDG brain PET/MR

  • Conference paper
  • First Online:
EMBEC & NBC 2017 (EMBEC 2017, NBC 2017)

Abstract

Attenuation correction is essential for image quantification in PET. At minimum, bone, soft tissue and air need to be included in MR-based attenuation correction (MRAC) of the head. Additional tissue classes might be beneficial to improve the accuracy of MRAC further. We studied the attenuation effect of nasal sinuses in MRAC by four attenuation maps and by assessment of regional PET quantification.

MR-based attenuation maps using 0.151 cm−1, CT template-based, 0.100 cm−1, 0.060 cm−1 for sinus attenuation coefficients were created. A volume of interest (VOI) analysis of MRAC reconstructed PET data was conducted. Relative difference against PET data reconstructed with CT-based attenuation correction (CTAC) was calculated. Bias ratio images across the subject group were studied.

The mean relative difference in the whole brain to CTAC reconstructed PET for each of the methods were as follows: -2.88 %, -3.16 %, -3.17 % and -3.42 %. The difference to CTAC reconstructed PET was not statistically significant (p>0.05) with any of the methods. The bias ratio images showed the largest differences in sinus region while gray matter activity remained largely unchanged. The maximum differences between the methods were 1.46 % and 2.35 % in the Cerebellum and in Gyrus Rectus.

Therefore, when investigating only the changes in the gray matter radioactivity in neurodegenerative diseases, there is no critical need to account for sinus attenuation for MRAC of the head in 18F-FDG brain PET/MR.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • 1. Mehranian A, Arabi H, and Zaidi H (2016) “Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities,” Med Phys 43:1130–1155,

    Google Scholar 

  • 2. Andersen F L, Ladefoged C N, Beyer T et al. (2014) “Combined PET/MR imaging in neurology: MR-based attenuation correction implies a strong spatial bias when ignoring bone,” Neuroimage 84:206–216

    Google Scholar 

  • 3. Keereman V, Holen R V, Mollet P et al. (2011) “The effect of errors in segmented attenuation maps on PET quantification,” Med Phys 38:6010–6019

    Google Scholar 

  • 4. Ladefoged C N, Benoit D, Law I et al. (2015) “Region specific optimization of continuous linear attenuation coefficients based on UTE (RESOLUTE): application to PET/MR brain imaging,” Phys Med Biol 60:8047–8065

    Google Scholar 

  • 5. Zaidi H, Montandon M-L, and Slosman D O (2003), “Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography,” Med Phys 30: 937–948

    Google Scholar 

  • 6. Burger C, Goerres G, Schoenes S et al. (2002) “PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients,” Eur J Nucl Med Mol Imag 29: 922–927

    Google Scholar 

  • 7. Teuho J, Linden J, Johansson J et al. (2016) “Tissue Probability-Based Attenuation Correction for Brain PET/MR by Using SPM8,” IEEE Trans Nucl Sci 63:2452–2463

    Google Scholar 

  • 8. Rorden C, Bonilha L, Fridriksson J et al. (2012) “Age-specific CT and MRI templates for spatial normalization,” Neuroimage, 61:957–965

    Google Scholar 

  • 9. Catana C, van der Kouwe A, Benner T, et al. (2010) “Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype,” J Nucl Med 51:1431–1438

    Google Scholar 

  • 10. Tzourio-Mazoyer N, Landeau B, Papathanassiou D et al. (2012) “Automated anatomical labeling of activations in SPM using a macroscopic anatomical parcellation of the MNI MRI single-subject brain,” Neuroimage 15:273–289

    Google Scholar 

  • 11. Ouyang J, Chun S Y, Petibon Y et al. (2013) “Bias Atlases for Segmentation-Based PET Attenuation Correction Using PET-CT and MR,”,” IEEE Trans Nucl Sci 60:3373–3382

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jarmo Teuho .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Cite this paper

Teuho, J., Tuisku, J., Linden, J., Teräs, M. (2018). Effect of sinus attenuation in MR-based attenuation correction in 18F-FDG brain PET/MR. In: Eskola, H., Väisänen, O., Viik, J., Hyttinen, J. (eds) EMBEC & NBC 2017. EMBEC NBC 2017 2017. IFMBE Proceedings, vol 65. Springer, Singapore. https://doi.org/10.1007/978-981-10-5122-7_67

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-5122-7_67

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-5121-0

  • Online ISBN: 978-981-10-5122-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics