A Combined Doppler Echocardiographic Investigation in Premature Infants with and without Respiratory Distress Syndrome

  • Chapter
Echocardiology

Part of the book series: Developments in Cardiovascular Medicine ((DICM,volume 13))

Abstract

Premature infants often develop the Respiratory Distress Syndrome (RDS). In the traditional view, this is due to a lack of surfactant causing a collapse of lung alveoli. In a number of cases of RDS, a Patent Ductus Arteriosus (PDA) with Left to Right (L-R) shunt is diagnosed during the recovery phase of the syndrome from the presence of a murmur, bounding pulses and an increased Left Atrium/Aorta ratio (LA/Ao). This diagnosis of the PDA has wrongly led to the conclusion that this L-R shunt first arises in the recovery phase; perhaps because routine clinical examination is not always sufficient to detect a PDA, since a large PDA with L-R shunt is not always acompanied by a heart murmur and even the echocardiographic demonstration of an increase in LA dimension or LA/Ao ratio is not conclusive evidence for the existence of a PDA with L-R shunt. Theoretically, a PDA with L-R shunt can cause respiratory problems, especially in small infants, as a result of pulmonary vessel engorgement, leading in turn to surfactant deficiency due to anoxaemia. So we have the situation indicated below:

SURFACTANT DEFICIENCY↔RDS↔PDA

In our investigation we demonstrated the existence of a PDA with L-R shunt in premature infants by means of a combined Doppler echocardiographic (DE) technique. The moment of closure of the ducus could be estimated from successive measurements. We also measured the LA/Ao ratio by means of echocardiography to determine the magnitude of the L-R shunt.

This research was sponsored by the Dutch Heart Foundation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Baker DW, EE Simeon, A Rubinstein, GS Lorch: Pulsed Doppler echocardiography: principles and applications. Amer J Med 63: 69–80, 1977.

    Article  PubMed  CAS  Google Scholar 

  2. Peronneau PA, JP Bournat, A Bugnon, A Barbat, M Xhaard: Theoretical and practical aspects of pulsed Doppler flowmetry: realtime application to the measure of instantaneous velocity profiles in vitro and in vivo. In: Cardiovascular applications of ultrasound ( Reneman RS, ed.). North-Holland Publishing Company, Amsterdam, 1974.

    Google Scholar 

  3. Stevenson JG, I Kawabori, WG Guntheroth: Noninvasive detection of pulmonary hypertension in patent ductus arteriosus by pulsed Doppler echocardiography. Circulation 60: 355–359, 1979.

    PubMed  CAS  Google Scholar 

  4. Goldberg SJ, HD Allen, DJ Sahn: Echocardiographic detection and management of patent ductus arteriosus in neonates with respiratory distress syndrome: two-and one-half year prospective study. J Clin Ultrasound 5: 161–169, 1977.

    Article  PubMed  CAS  Google Scholar 

  5. Recommendation of the American Society of Echocardiography regarding Quantitation in M-Mode Echocardiography. 7 March 1978.

    Google Scholar 

  6. Silverman NH, AB Lewis, MA Heyman, AM Rudolph: Echocardiographic assessment of Ductus Arteriosus Shunt in Premature Infants. Circulation 50: 821–825, 1974.

    PubMed  CAS  Google Scholar 

  7. Daniëls O, JCW Hopman, GBA Stoelinga, HJ Busch, PGM Peer: Doppler flow characteristics in the main pulmonary artery and left atrial size before and after ductal closure in healthy newborns, Pediatric Cardiology (In revision).

    Google Scholar 

  8. Warburton D, EF Bell, W Oh: Pharmacokinetics and echocardiographic effects of digoxin in low birth weight infants with left-to-right shunting due to patent ductus arteriosus. Dev Pharmacol Ther 1: 189–200, 1980.

    PubMed  CAS  Google Scholar 

  9. Björkhem GE, NR Lundström, NW Svenningsen: Influence of continous positive airways pressure treatment on ductus arteriosus shunt assessed by echocardiography. Arch Disease Childhood 52: 659–661, 1977.

    Article  Google Scholar 

  10. Sahn DJ, Y Vaucher, DE Williams, HD Allen, SJ Goldberg, WF Friedman: Echocardiographic detection of large left to right shunts and cardiomyopathies in infants and children. Amer J Cardiol 38: 73–79, 1976.

    Article  PubMed  CAS  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1981 Martinus Nijhoff Publishers, The Hague

About this chapter

Cite this chapter

Daniëls, O., Hopman, J.C.W., Stoelinga, G.B.A., Busch, H.J., Peer, P.G.M. (1981). A Combined Doppler Echocardiographic Investigation in Premature Infants with and without Respiratory Distress Syndrome. In: Rijsterborgh, H. (eds) Echocardiology. Developments in Cardiovascular Medicine, vol 13. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-8299-4_45

Download citation

  • DOI: https://doi.org/10.1007/978-94-009-8299-4_45

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-009-8301-4

  • Online ISBN: 978-94-009-8299-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics