Abstract
The Bonn/Stuttgart group presented in 1973 results of the first comprehensive study on computer-aided tissue characterization on the eye in vitro, using empirical analysis of video (A-mode)-signals*** (Trier and Reuter 1973; Decker et al. 1973). 1973–1977, techniques for utilization of RF-signals in the 5–25 MHz frequency range were developed for the same applications** (Trier 1974; BMFT-DFVLR, Final report 1978). In the period 1977–81, the developed system and the techniques for RF-signal acquisition and processing were tested in vivo in clinical routine on the eyes of patients and volunteers by the Bonn group (BMFT-DFVLR, Final Report 1982). For that purpose the techniques for data collection, A/D conversion, intermediate storage, data structure, system controls, and processing methods were continuously adapted to the clinical needs. Preliminary results were presented at the SIDUO VII and VIII Conferences (Decker and Trier 1979; Trier et al. 1981).
Eye Clinic, Univ. Bonn (FRG); the authors H. G. Trier, M. Kottow, R. D. Lepper, R. Reuter, R. Müller-Breitenkamp and K. J. Otto were formerly affiliated to: Klinisches Institut für experimentelle Ophthalmologie der Universität Bonn
Institut für Biomedizinische Technik d. Univ. Stuttgart (FRG)
supported by Stiftung Volkswagenwerk
supported by BMFT-DFVLR, Bonn Germany
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
BMFT-DFVLR, Grants 01 VI 014 and 034-B 13 MT 224 a, Final Report Sept. 20, 1978
BMFT-DFVLR, Grants 01 VI 047 and 057 — ZA/NT/MT 224 a, Final Report July 30, 1982
Cords, S. (in preparation) Dissertation, Bonn
Decker, D., Epple, E., Leiss, W. and Nagel, M.: Digital computer analysis of time amplitude ultrasonograms from the human eye. II. Data processing. J. Clin. Ultrasound 1,156–159 (1973).
Decker, D. and Trier, H. G.: Das Projekt ‘rechnergestützte Gewebsdifferenzierung’ der Arbeitsgemeinschaft Bonn/Stuttgart. II. Ergebnisse der Anwendung an dünnen Gewebsschichten im Auge. Proc. SIDOU VII, Münster 1978, in: Diagnostica Ultrasonica in Ophthalmologia, (Gernet, H., ed.) Remy, Münster 1979, pp. 40–43.
Decker, D. and Irion, K.: A-mode RF-signal analysis (frequency domain). In: Ultrasonic Tissue Characterization. Clinical Achievements and Technological Potentials. (Thijssen, J. M., ed.) Stafleu’s Scientif. Publ. Comp., Alphen a.d.R., Brussels, 1980, pp. 231–244.
Decker, D., Trier, H. G., Irion, K., Lepper, R. D. and Reuter, R.: Rechnergestützte Gewebsdifferenzierung am Auge. Ultraschall 1, 284–296 (1980).
Decker, D., Faust, U. and Irion, K.: Examination of thin tissue layers in the human eye. Med. Progr. Techn. 8, 83–91 (1981).
Irion, K. and Decker, D.: Estimation of the acoustic attenuation of i.o. tumours in vivo. 2nd Workshop on ultrasonic tissue characterization, Nijmegen 1981 (in press).
Kuc, R. and Schwartz, M.: Estimating the acoustic attenuation coefficient slope for liver from reflected ultrasound signals. IEEE Trans. Biomed. Engin. 25, 321–344 (1978).
Lepper, R. D., Reuter, R. and Trier, H. G.: Digitization of high-frequency ultrasonic signals for tissue differentiation in ophthalmology. Biomed. Techn. 23, 75–78 (1978).
Lepper, R. D., Trier, H. G. and Reuter, R.: Ultrasonic measurements at the posterior wall of living human eyes. Ophthal. Res. 13, 1–11 (1981).
Lepper, R. D.: Unpublished results (1981).
Lepper, R. D.: Computergestützte Qualitätsbeurteilung von Ultraschallwandlern in der medizinischen Diagnostik. Biomed. Techn. 27, 2–6 (1982).
Purnell, E. W.: Ultrasonic biometry of the posterior ocular coats. Trans. Amer. Ophthal. Soc. 78, 1027–1078 (1980).
Trier, H. G. and Reuter, R.: Digital computer analysis of time-amplitude ultrasonograms from the human eye. I. Signal acquisition. J. Clin. Ultrasound 1, 150–154 (1973).
Trier, H. G.: Gewebsdifferenzierung mit Ultraschall. Habil. schr. 1974 and Bibl. Ophthal. No. 86, Karger, Basel 1977.
Trier, H. G.: Ultrasonic tissue characterization in the eye and orbit. In: Ultrasonic Tissue Characterization: Clinical Achievements and Technological Potentials. (Thijssen, J. M., ed.) Stafleu’s Scientif. Publ. Comp., Alphen a.d.R., Brussels, 1980, pp. 45–67.
Trier, H. G., Decker, D., Müller-Breitenkamp, R., Irion, K. and Otto, K. J.: The recognition of detached retina and vitreous membranes by means of radio frequency signal analysis. Proc. SIDUO VIII, Nijmegen 1980, in: Ultrasonography in Ophthalmology (Thijssen, J. M. and Verbeek, A. M., eds.) Junk Publ. The Hague, Boston, London 1981, pp. 419–430.
Weigelin, E. and Trier, H. G.: Méthodes objectives de caractérisation tissulaire aux ultra-sons prospectives d’application cliniques en ophtalmologie. Bull. Soc. franc. Ophtal. 93, 332–335(1981).
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1983 Dr W. Junk Publishers, The Hague/Boston/Lancaster
About this paper
Cite this paper
Trier, H.G. et al. (1983). Ocular Tissue Characterization by RF-Signal Analysis: Summary of the Bonn/Stuttgart in Vivo-Study. In: Hillman, J.S., Le May, M.M. (eds) Ophthalmic Ultrasonography. Documenta Ophthalmologica Proceedings Series, vol 38. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-7278-0_58
Download citation
DOI: https://doi.org/10.1007/978-94-009-7278-0_58
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-7280-3
Online ISBN: 978-94-009-7278-0
eBook Packages: Springer Book Archive