Summary
It was demonstrated how serious malfunctions of diagnostic ultrasonic equipment can be detected with the help of simple acoustic and electronic performance measurements. Furthermore, the benefit of these measurements for computer-assisted A-scan signal analysis was shown. A low-cost minicomputer system could be used to gain additional tissue differentiation data. These were — to a certain degree of approximation — free from the individual characteristics of the ultrasound system used, thus making diagnostic findings easier to be compared and valid in a more general sense.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Buschmann, W., Linnert, D. and Eysholdt, E. Measurement of Equipment Sensitivity in Diagnostic Ultrasonography. In: Ultrasound in Medicine, Vol. 3B. (D. White and R. Brown eds.) New York: Plenum Publishing Corp. (1977) p. 1925.
Haigis, W. and Buschmann, W. Klinisch anwendbare Methoden zur Uberprflfung von diagnostisch relevanten Gerateparametern von Impuls-Echo-Geraten. In: Ultra-schalldiagnostik in der Medizin, ed: G. Rettenmaier, E.-G. Loch, M. Hansmann, H. G. Trier, Georg Thieme Verlag, Stuttgart, New York (1981) p. 253.
Haigis, W., Reuter, R., Lepper, R.-D. Comparative Measurements on Different Pulse-Echo Systems Using Test Reflectors. In: Ultrasonography in Ophthalmology 8, Proc. of the SIDUO VIII Symposium, Nijmegen, 1980. J. M. Thijssen and A. M. Verbeek, eds., Doc. Ophthal. Proc. Series, Vol. 29. Junk, Den Haag (1981) p. 445.
Haigis, W., Schneider, S., Reuter, R. Halbautomatische, rechnergesttltzte Kalibrierungs-messungen an diagnostischen Ultraschallgeraten (1982), to be published
International Electrotechnical Commission, Tech. Comm. 29: Electroacousties, Sub-Comm. 29D: Ultrasonics. Draft: Methods of measuring the performance of ultrasonic pulse-echo diagnostic equipment (1979).
Ossoinig, K. C. and Patel, J. H. A-Scan Instrumentation for Acoustic Tissue Differentiation. In: Ultrasound in Medicine, Vol. 3B (D. White and R. Brown, eds.) New York: Plenum Publishing Corp. (1977) p. 1955.
Reuter, R., Trier, H. G., Lepper, R.-D. Ein elektrisches Prtifverfahren und Prtlfgerat ftir Ultraschalldiagnostik-Anlagen. In: Medizinal-Markt/Acta Medicotechnica, 28. Jahrgang, Nr. 2 (1980) p. 58.
Reuter, R., Lepper, R.-D. Haigis, W. Comparative Measurements on Ultrasonic Pulse-Echo Equipment with the ECHOSIMULATOR. In: Ultrasonography in Ophthalmology 8, Proc. of the SIDUO VIII Symposium, Nijmegen, 1980. J. M. Thijssen and A. M. Verbeek, eds., Doc. Ophthal. Proc. Series Vol. 29. Junk, Den Haag (1981) p.463.
Thijssen, J. M. (ed.) Ultrasonic Tissue Characterization, Stafleu’s Scientific Publishing Company, Alphen aan den Rijn/Brussels (1980).
Thijssen, J. M. and Verbeek, A. M. Computer analysis of A-mode echograms from choroidal melanoma. In: Ultrasonography in Ophthalmology 8, Proc. of the SIDOU VIII Symposium, Nijmegen, 1980, J. M. Thijssen and A. M. Verbeek, eds., Doc. Ophthal. Proc. Series Vol. 29. Junk, Den Haag (1981) p. 123.
Trier, H. G. Lichtdurchlassige, feststoffahnlich bearbeitbare Kunststoffe mit Schall-geschwindigkeiten unter 2000 m/sec. In: Proc. I. Weltkongress Ultraschalldiagnostik Med. und SIDOU III Vol. 2 (1969) p. 199.
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1983 Dr W. Junk Publishers, The Hague/Boston/Lancaster
About this paper
Cite this paper
Haigis, W., Buschmann, W. (1983). Performance Measurements and Quantitative Echography. In: Hillman, J.S., Le May, M.M. (eds) Ophthalmic Ultrasonography. Documenta Ophthalmologica Proceedings Series, vol 38. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-7278-0_55
Download citation
DOI: https://doi.org/10.1007/978-94-009-7278-0_55
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-7280-3
Online ISBN: 978-94-009-7278-0
eBook Packages: Springer Book Archive