Abstract
Two new non-isothermal methods for generating kinetic data for food constituents are examined. The first consists of a stirred batch reactor using linearly increasing temperature. The second employs a continuous flow reactor and a novel thermal evaluation method for defining the thermal treatment. The significance and implications of both methods are examined as related to each other and to classical data generation methods.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Ball, H.R. Jr., Hamid-Samimi, M., Foegeding, P.M., Swartzel, K.R. 1987. Functionality and microbial stability of ultra pasteurized, aseptically packaged refrigerated whole egg. J. Fd. Sci. 52:1212–1218.
Hawran, L.J., Jones, V.A., and Swartzel, K.R. 1985. Sediment formations in aseptically processed and packaged milk. J. Fd. Proc. and Pres. 9:189–207.
Rhim, J.W., 1988. Kinetic Studies of Thermal Evaluation Indicators of Dairy Products and Development of a New Kinetic Data Generation Method. Ph.D. thesis, N.C. State University, Raleigh.
Sadeghi, F., Hamid-Samimi, H.M. and Swartzel, K.R. 1986. Micro-computer program for determining the unique time-temperature associated with the equivalent point method of thermal evaluation. J. Fd. Proc. and Pres. 10:331–335.
Sadeghi, F. and Swartzel, K.R. 1988. Calibration materials for thermal systems. J. Fd. Sci. (in press).
Sadeghi, F. and Swartzel, K.R. 1988. Kinetic parameter determination at high temperature—a technique comparison study. J. Fd. Sci. (in press).
Swartzel, K.R. 1982. Arrhenius kinetics as applied to product constituent losses in Ultra High Temperature processing. J. Fd. Sci. 47:1886–1871.
Swartzel, K.R. 1983a. A method for predicting gelation of aseptically packaged steam injected UHT milk. J. Fd. Sci. 48:1376–1377.
Swartzel, K.R. 1983b. Tubular heat exchanger fouling by milk during Ultra High Temperature processing. J. Fd. Sci. 48:1507–1511.
Swartzel, K.R. 1983c. The role of heat exchanger fouling in the formation of sedimentation of UHT processed and packaged milk. J. Fd. Proc. & Pres. 7:247–257.
Swartzel, K.R. 1984. A continuous flow procedure for kinetic data generation. J. Fd. Sci. 49:803–806.
Swartzel, K.R. 1985. Generation, interpretation and use of kinetic data in the design and evaluation of aseptic systems. In Symposium Proceeding of the IUFoST Symposium on Aseptic Processing and Packaging of Foods, Tylosand, Sweden, Univ. of Lund, Lund, Sweden.
Swartzel, K.R. and Jones, V.A 1985. Systems design and calibration of a continuous flow apparatus for kinetic studies. J. Fd. Sci. 50:1203–1204.
Swartzel, K.R. 1986. An equivalent point method for thermal evaluation of continuous flow systems. J. of Agri. and Fd. Chem. 34:396–401.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1989 Kluwer Academic Publishers
About this chapter
Cite this chapter
Swartzel, K.R. (1989). Non-Isothermal Kinetic Data Generation for Food Constituents. In: Singh, R.P., Medina, A.G. (eds) Food Properties and Computer-Aided Engineering of Food Processing Systems. NATO ASI Series, vol 168. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-2370-6_5
Download citation
DOI: https://doi.org/10.1007/978-94-009-2370-6_5
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-7567-1
Online ISBN: 978-94-009-2370-6
eBook Packages: Springer Book Archive