Skip to main content

On the accuracy of densitometric measurements of coronary artery stenosis based on Lambert-Beer’s absorption law

  • Chapter
New Developments in Quantitative Coronary Arteriography

Part of the book series: Developments in Cardiovascular Medicine ((DICM,volume 87))

Summary

Densitometry of coronary arteries is often thought to be independent of the size and shape of the lumens involved. This belief results from the postulation that Lambert-Beer’s absorption law (LB’s law) is the appropriate theoretical basis for densitometric measurements on coronary arteries. Experiments with certain phantoms yield, however, results incompatible with the LB-model. For instance, a dependence of the obtained degrees of stenosis on the respective size, shape and rotational orientation (i.e. around the vessel axis and with respect to the incident X-rays) of the lumens can be observed. Since this dependence is not removed by compensation for the nonlinearity introduced by the cinefilm, one must admit that LB’s law is not the adequate basis for densitometric measurements of coronary artery stenosis, and that conventional densitometry (i.e. based on LB’s law) is likely to produce systematic errors. Using a previously designed, more adequate mathematical-physical model which takes X-ray polychromasy and scattered radiation into account, the magnitude of errors of conventionally obtained degrees of stenosis was assessed, as well as the magnitude of errors affecting the residual luminal area, this latter one being obtained from the erroneously assessed degree of stenosis and the area of the intact lumen (determined itself by calibrated diameter measurement).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 16.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. Wollschläger H, Zeiher AM, Lee P, Solzbach U, Bonzel T, Just H: Computed ‘triple’ orthogonal projections for optimal radiological imaging with biplane X-ray systems. Comput Cardiol, 1986, (in press)

    Google Scholar 

  2. Doriot PA, Pochon Y, Rasoamanambelo L, Chatelain P, Welz R, Rutishauser W: Densitometry of coronary arteries — An improved physical model. Comput Cardiol: 91–94, 1985.

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1988 Kluwer Academic Publishers

About this chapter

Cite this chapter

Doriot, PA., Rutishauser, W. (1988). On the accuracy of densitometric measurements of coronary artery stenosis based on Lambert-Beer’s absorption law. In: Reiber, J.H.C., Serruys, P.W. (eds) New Developments in Quantitative Coronary Arteriography. Developments in Cardiovascular Medicine, vol 87. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-1309-7_7

Download citation

  • DOI: https://doi.org/10.1007/978-94-009-1309-7_7

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-010-7082-9

  • Online ISBN: 978-94-009-1309-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics