Abstract
There is increasing interest in the use of highly cross-linked polyethylene with large diameter heads in the hip. This study investigated the wear characteristics of size 36 mm ceramic and cobalt chrome femoral heads articulating against highly cross-linked polyethylene inserts using a physiological hip simulator. The steady state wear rate of the ceramic femoral heads articulating against highly cross-linked inserts was found to be 50% lower than that of cobalt chrome femoral heads.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
D’Lima DD, Hermida JC, Chen PC, Colwell Jr CW (2003) Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator. J Orthop Res 21:761–766.
Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P (2004) Highly cross-linked polyethylene in total hip arthroplasty. Clin Orthop Rel Res 429:6–16.
Dowson D (2001) New joints for the Millennium: wear control in total replacement joints. Proc Instn Mech Engrs 215H:335–358.
Endo M, Tipper JL, Barton DC, Stone MH, Ingham E, Fisher J (2002) Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proc Instn Mech Engrs 216H:111–122.
Galvin AL, Tipper JL, Jennings LM, Stone MH, Jin ZM, Ingham E, Fisher J (in press) Wear and biological activity of highly cross-linked polyethylene in the hip under low serum protein concentrations. Proc Instn Mech Engrs Part H.
Muratoglu OR, Bragdon CR, O’Connor DO, Perinchief RS, Estok II DM, Jasty M, Harris WH (2001) Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene. J Arthroplasty 16:24–30.
Williams S (2003) Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation. Proc Instn Mech Engrs 217H:147–153.
Wroblewski BM, Siney PD, Fleming PA (2005) Low-friction arthoplasty of the hip using alumina ceramic and cross-linked polyethylene. JBJS (Br) 87-B:1220–1.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2006 Steinkopff Verlag, Darmstadt
About this paper
Cite this paper
Fisher, J., Jennings, L.M., Galvin, A.L. (2006). Wear of Highly Crosslinked Polyethylene against Cobalt Chrome and Ceramic femoral heads. In: Benazzo, F., Falez, F., Dietrich, M. (eds) Bioceramics and Alternative Bearings in Joint Arthroplasty. Ceramics in Orthopaedics. Steinkopff. https://doi.org/10.1007/978-3-7985-1635-9_29
Download citation
DOI: https://doi.org/10.1007/978-3-7985-1635-9_29
Publisher Name: Steinkopff
Print ISBN: 978-3-7985-1634-2
Online ISBN: 978-3-7985-1635-9
eBook Packages: MedicineMedicine (R0)