Skip to main content

Screws and Plates and Their Application

  • Chapter
Manual of INTERNAL FIXATION

Abstract

Screws are used either to fasten plates or similar devices onto bone, or, as lag screws, to hold together fragments of bone.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 99.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Allgöwer M, Matter P, Perren SM, Rüedi T (1973) The dynamic compression plate. Springer, Berlin Heidelberg New York

    Book  Google Scholar 

  • Ansell RH, Scales JT (1968) A study of some factors which affect the strength of screws and their insertion and holding power in bone. J Biomechanics 1: 279–302

    Article  CAS  Google Scholar 

  • Charnley J (1953) Compression arthrodesis. Livingstone, Edinburgh

    Google Scholar 

  • Danis R (1947) Theorie et pratique de l’ostéosynthèse. Masson, Paris

    Google Scholar 

  • Gozna ER, Harrington IJ (1982) Biomechanics of musculoskeletal injury. Williams and Wilkins, Baltimore London

    Google Scholar 

  • Key JA (1932) Positive pressure in arthrodesis for tuberculosis of the knee joint. South Med J 25: 909–915

    Article  Google Scholar 

  • Müller ME, Allgöwer M, Schneider R, Willegger W (1979) Manual of internal fixation, 2nd edn. Springer, Berlin Heidelberg New York

    Book  Google Scholar 

  • Pauwels F (1935) Der Schenkelhalsbruch, ein mechanisches Problem. Enke, Stuttgart

    Google Scholar 

  • Phillips JH, Rahn BA (1989) Comparison of compression and torque measurements of self-tapping and pre-tapped screws. Plast Reconstruct Surg 83: 447–4556

    Article  CAS  Google Scholar 

  • Regazzoni P, Rüedi T, Winquist R, Allgöwer M (1985) The dynamic hip screw implant system. Springer, Berlin Heidelberg New York

    Book  Google Scholar 

  • Schatzker J, Sanderson R, Murnaghan P (1975 a) The holding power of orthopaedic screws in vivo. Clin Orthop 108: 115–126

    Google Scholar 

  • Schatzker J, Horn JG, Sumner-Smith G (1975 b) The effects of movement on the holding power of screws in bone. Clin Orthop 111: 257–263

    Google Scholar 

  • Schatzker J, Horn JG, Sumner-Smith G (1975 c) The reaction of cortical bone to compression by screw threads. Clin Orthop 111: 263–265

    Google Scholar 

  • Schatzker J, Manley PA, Sumner-Smith G (1980) In vivo strain gauge study of bone response to loading with and without internal fixation. In: Uhthoff H (ed) Current concepts of internal fixation of fractures. Springer, Berlin Heidelberg New York, pp 306–314

    Google Scholar 

  • Schenk R, Willenegger H (1964) Histologie der primären Knochenheilung. Langenbecks Arch Klin Chir 308: 440–452

    CAS  Google Scholar 

Download references

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 1991 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Schatzker, J. (1991). Screws and Plates and Their Application. In: Manual of INTERNAL FIXATION. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-02695-3_3

Download citation

  • DOI: https://doi.org/10.1007/978-3-662-02695-3_3

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-08091-3

  • Online ISBN: 978-3-662-02695-3

  • eBook Packages: Springer Book Archive