Skip to main content

A Clinical Evaluation of an Intraparenchymal Intracranial Pressure Transducer

  • Conference paper
Intracranial Pressure VIII

Abstract

The Camino pressure transducer is accurate experimentally over a range of clinically relevant intracranial pressures (ICPs). Three clinical studies have shown that intraparenchymal pressure mirrors intraventricular pressure. In two a different type of transducer was used, and one was a mixed animal and human study [3, 4, 2]. This study compares intraparenchymal pressure, measured with a Camino fibre-optic transducer, with intraventricular pressure, using a fluid filled catheter, in unconscious head injured patients and evaluates the clinical efficacy of the Camino system.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Altman DG, Bland JM (1983) Measurement in medicine: the analysis of method comparison studies. The Statistician 32:307–317

    Article  Google Scholar 

  2. Ostrup RC, Luerssen TG, Marshall LF, Zornow MH (1987) Continuous monitoring of intracranial pressure with a miniturized fibre optic device. J Neurosurg 67:206–209

    Article  PubMed  CAS  Google Scholar 

  3. Piek J, Bock WJ (1990) Continuous monitoring of cerebral tissue pressure in neurosurgical practice-experiences with 100 patients. Intensive Care Medicine 16(3): 184–188

    Article  PubMed  CAS  Google Scholar 

  4. Sundbarg G, Nordstrom C-H, Messeter K, Soderstrom S (1987) A comparison of intra-parenchymatous and intraventricular pressure recording in clinical practice. J Neurosurg 67:841–845

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1993 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Statham, P., Midgley, S., Dearden, N.M., McIntosh, C., Miller, J.D. (1993). A Clinical Evaluation of an Intraparenchymal Intracranial Pressure Transducer. In: Avezaat, C.J.J., van Eijndhoven, J.H.M., Maas, A.I.R., Tans, J.T.J. (eds) Intracranial Pressure VIII. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-77789-9_2

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-77789-9_2

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-77791-2

  • Online ISBN: 978-3-642-77789-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics