Summary
A porous steroid-eluting electrode gives stable, low chronic thresholds without peaking in animal studies. Controlled steroid release at the tissue-electrode interface affects only a few myocardial cells, precluding systemic side effects. Human studies so far confirm the animal results. This will allow the use of much lower pulse generator voltage and pulse width without compromising safety. When combined with appropriate pacing circuits, the new electrode’s low polarization characteristics may allow reliable capture detection.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Irnich W: Comparison of Pacing Electrodes of Different Shape and Material Recommendations, Pace, 1983; 6: 422–426.
Stokes KB and Stephenson NL: The Implantable Cardiac Pacing Lead - Just a Simple Wire? In The Third Decade of Cardiac Pacing, Barold SS and Mugica J (Eds), Mount Kisko, NY, Futura, 1982: 365–416.
Pirzada FA and Seltzer J: Clinical Experience With the Medtronic 6971 Polyurethane Lead, Pace 1983: 6 (Abstract).
Preston T A and Judge RD: Alteration of Pacemaker Threshold by Drug and Physiological Factors. Ann NY Acad Sci 1969; 167: 686–692.
Sowton E and Barr I: Physiological Changes in Threshold. Ann NY Acad Sci, 1969; 167: 679–685.
Gettes LS, Shabetai R, Downs TA, et al: Effect of changes in potassium and calcium concentrations on diastolic threshold and strength interval relationships of the human heart. Ann NY Acad Sci, 1969; 167: 693–705.
Beanlands DS, Akyurekli Y and Keon WJ: Prednisone in the management of exit block. In Meere, C (ed) Proceedings of the VI World Symposium on Cardiac Pacing. Montreal, Pacesymp, 1979, Chapter 18–3.
Thiele G, Lachmann W, Eschemann et al: Zur Beeinflussung des Reizschwellenanstieges nach Herzschrittmacher Implantation durch Prednisolon. Zeitschrift für die gesamte Innere Medizin. 1980; 35: 863–866.
Gordon S, Timmis GE, Westveer DE, et al: A New Low Threshold Steroid-Eluting Pacing Lead. Proceedings, VII World Symposium on Cardiac Pacing.
Parsonnet V and Werres R: Clinical Experience With a Porous-Tip Steroid-Loaded Ventricular Pacing Electrode. Pace 1983; 6: 319 (abstract).
Stokes KB, Kriett JM, Gornick CA, et al: Low Threshold Cardiac Pacing Electrodes. Accepted for Proceedings - Fifth Annual Conference IEEE Engineering in Medicine and Biology Society, 1983.
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1983 Dr. Dietrich Steinkopff Verlag, GmbH & Co. KG, Darmstadt
About this paper
Cite this paper
Stokes, K.B., Bornzin, G.A., Wiebusch, W.A. (1983). A Steroid-Eluting, Low-Threshold, Low-Polarizing Electrode. In: Steinbach, K. (eds) Cardiac Pacing. Steinkopff, Heidelberg. https://doi.org/10.1007/978-3-642-72367-4_55
Download citation
DOI: https://doi.org/10.1007/978-3-642-72367-4_55
Publisher Name: Steinkopff, Heidelberg
Print ISBN: 978-3-642-72369-8
Online ISBN: 978-3-642-72367-4
eBook Packages: Springer Book Archive