Abstract
Specific and sensitive detection or precise quantification of xenobiotics in biosamples (e.g. blood, urine, saliva, sweat, hair) are great challenges in analytical toxicology. GC-MS is the most sensitive, specific and universal analytical method for low mass xenobiotics. Precise quantification can be performed using the selected ion mode (SIM) and stable isotopes as internal standards. Negative chemical ionization (NCI) can improve several fold the sensitivity for the determination of compounds with electronegative sites (e.g. halogens). For screening and identification of most of the basic and neutral drugs (e.g. drugs of abuse, psychotropics, hypnotics, analgesics, cardiacs) in urine, a systematic toxicological analysis procedure (STA) was developed using GC-MS after acid hydrolysis, extraction and acetylation. For detection of acidic xenobiotics (e.g. anticoagulants, ACE inhibitors, diuretics, antirheumatics) in urine, a further GC-MS procedure was developed using extractive alkylation. For the detection of non-volatile xenobiotics (e.g. toxic peptides like α- and ß-amanitin or phase II metabolites) electrospray LC-MS procedures were developed. The procedures and examples show that in analytical toxicology GC-MS is the method of choice for low mass xenobiotics while LC-MS is that for non-volatiles.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Arlt JW, Maurer HH (1996) On the toxicological detection of 4-hydroxycoumarin anticoagulants and their metabolites in urine by GC-MS after extractive alkylation. Proceedings of the 32nd Intern. Meeting of TIAFT. Interlaken, August 1996, in press.
De la Torre R, Ortuno J, Gonzalez ML, Farre M, Carni J, Segura J (1995) Determination of cocaine and its metabolites in human urine by GC/MS after simultaneous use of cocaine and ethanol. J Pharm Biomed Anal 13:305–312.
De Zeeuw RA (1989) Modern chromatographic procedures in systematic toxicological analysis. J Chromatogr 488:199–213.
Ensslin HK, Kovar K-A, Maurer HH (1996a) Toxicological detection of the designer drug 3,4-methylenedioxyethylamphetamine (MDE, “Eve”) and its metabolites in urine by FPIA and GC-MS. J Chromatogr B 683:189–197.
Ensslin HK, Maurer HH, Gouzoulis E, Hermie L, Kovar K-A (1996b) Metabolism of racemic MDE in humans. Drug Metabol Dispos 24, in press.
Gonzalez G, Ventura R, Smith AK, De la Torre R, Segura J (1996) Detection of anti-inflammatory drugs in plasma and urine by GC-MS. J Chromatogr A 719:251–264.
Maurer HH (1992a) Review: Systematic toxicological analysis of drugs and their metabolites by gas chromatography-mass spectrometry. J Chromatogr 580:3–41.
Maurer HH (1992b) Methods for GC-MS. In: Pfleger K, Maurer HH, Weber A (eds), Mass spectral and GC data of drugs, poisons, pesticides, pollutants and their metabolites, 2nd ed, part 1. VCH publishers, Weinheim, pp 3–32.
Maurer HH (1996) On the metabolism and the toxicological analysis of designer drugs. Ther Drug Monit 18:465–470.
Maurer HH, Kraemer T (1992) Toxicological detection of selegiline and its metabolites in urine using fluorescence polarisation immunoassay (FPIA) and GC-MS and differentiation by enantioselective GC-MS of the intake of selegiline from an abuse of methamphetamine or amphetamine. Arch Toxicol 66:675–678.
Maurer HH, Kraemer T, Ledvinka O, Schmitt CJ, Weber AA (1996) Gas chromatography- mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) toxicological analysis. Studies on the detection of clobenzorex and its metabolites within a systematic toxicological analysis procedure by GC-MS and by immunoassay, and studies on the detection of α- and β-amanitin by atmospheric pressure ionization electrospray LC-MS. J Chromatogr. B, in press.
Moeller MR, Fey P, Rimbach S (1992) Identification and quantification of cocaine and its metabolites, benzoylecgonine and ecgonine methyl ester, in hair of Bolivian coca chewers by GC/MS. J Anal Toxicol 16:291–296.
Pfleger K, Maurer HH, Weber A (1992) Mass spectral and GC data of drugs, poisons, pesticides, pollutants and their metabolites, 2nd ed. VCH publishers, Weinheim.
Pfleger K, Maurer HH, Weber A (1997) Mass spectral library of drugs, poisons, pesticides, pollutants and their metabolites, 3rd ed. Hewlett Packard, Palo Alto, in prep.
Solans A, Carnicero M, De la Torre R, Segura J (1995) Comprehensive screening procedure for detection of stimulants, narcotics, adrenergic drugs, and their metabolites in human urine. J Anal Toxicol 19:104–114.
Tagliaro F, Smith FP, Turrina S, Equisetto V, Marigo M (1996) Complementary use of capillary zone electrophoresis and micellar electrokinetic capillary chromatography for mutual confirmation of results in forensic drug analysis. J Chromatogr A, in press.
Tracqui A, Kintz P, Mangin P (1995) Systematic toxicological analysis using HPLC/DAD. J Forensic Sci 40:254–262.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Additional information
Dedicated to Prof. Dr. R. Klaus Müller, Leipzig, on the occasion of his 60th birthday
Rights and permissions
Copyright information
© 1997 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Maurer, H.H., Arlt, J.W., Kraemer, T., Schmitt, C.J., Weber, A.A. (1997). Analytical Development for Low Molecular Weight Xenobiotic Compounds1 . In: Seiler, J.P., Vilanova, E. (eds) Applied Toxicology: Approaches Through Basic Science. Archives of Toxicology, vol 19. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-60682-3_17
Download citation
DOI: https://doi.org/10.1007/978-3-642-60682-3_17
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-64505-1
Online ISBN: 978-3-642-60682-3
eBook Packages: Springer Book Archive