MIT rule is one of the basic techniques of adaptive control. It can be embedded into a general scheme of circuit with MRAC structure (reference adaptive controller). This paper deals with simulation of MRAC by use of MIT rule for a superheater which is a crucial part of a coal-fired power plant. A superheater has been chosen as a typical practical real plant with time-variant parameters and thus suitable to be controlled by adaptive control mechanism. The paper gives a comparison of adaptive control with MRAC and original PID control currently implemented in a chosen output superheater in Detmarovice power plant. Matlab&Simulink environment is used for a simulation of the control circuit described in this paper.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Nevriva, P., Ozana, S., Pies, M., Vilimec, L.: Dynamical Model of a Power Plant Superheater. WSEAS Transactions on Systems 9(7), 774–783 (2010), http://www.wseas.us/e-library/transactions/systems/2010/89-878.pdf ; ISSN:1109-2777
Nevriva, P., Ozana, S., Pies, M.: Simulation of Power Plant Superheater Using Advanced Simulink Capabilities. International Journal of Circuits, Systems and Signal Processing, dostupnýz 5(1), 86–93 (2011), http://www.naun.org/journals/circuitssystemssignal/19-545.pdf ; ISSN: 1998-4464
Nevriva, P., Ozana, S., Vilimec, L.: Verification of the Dynamical Model of a Power Plant Superheater. In: Kallel, A., et al. (eds.) Advances in Dynamical Systems and Control: 6th WSEAS International Conference on Dynamical Systems and Control (CONTROL 2010), pp. S54–S59. WSEAS Press, Kantaoui (2010); ISBN: 978-960-474-185-4, ISSN: 1790-5117
Ozana, S., Pies, M.: Modeling and Simulation of Power Plant Superheater in Simulink. In: Proceedings of the International Conference on Circuits, Systems, Signals (CSS 2010), Sliema, Malta, September 15- 17, pp. 180–183 (2010); ISBN: 978-960-474-226-4, ISSN: 1792-4324
Martin, P.I.E.Å .: Ozana, S. Simulation of Power Plant Superheater by Simulink S-functions. In: 15th IEEE International Conference on Emerging Technologies and Factory Automation (ETFA 2010), 1x CD-ROM, September 13-16. Escuela Técnica Superior de IngenierÃa de Bilbao, Bilbao (2010); ISBN: 978-142446850-8
Astrom, K.J., Wittenmark, B.: Adaptive Control, 2nd edn. Addison-Wesley (1989,1994)
ŠImandl, M.: Adaptivnà systémy, ZČU Plzeň (1993); ISBN: 80-7082-098-5
Cez Group. The Detmarovice Power Station (2011), http://www.cez.cz/en/powerplants-and-environment/coal-fired-powerplants/cr/detmarovice.html (cit. March 8, 2003)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag GmbH Berlin Heidelberg
About this chapter
Cite this chapter
Machacek, Z., Pies, M., Ozana, S. (2012). Simulation of MIT Rule-Based Adaptive Controller of a Power Plant Superheater. In: Sambath, S., Zhu, E. (eds) Frontiers in Computer Education. Advances in Intelligent and Soft Computing, vol 133. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-27552-4_65
Download citation
DOI: https://doi.org/10.1007/978-3-642-27552-4_65
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-27551-7
Online ISBN: 978-3-642-27552-4
eBook Packages: EngineeringEngineering (R0)