Navigation systems based on intra-operative ultrasound have been introduced for different surgical procedures and interventions. The accuracy of the ultrasound probe calibration is a main contribution to the overall accuracy of the navigation system. Different calibration methods based on phantoms have been introduced. The challenge of the calibration procedure is to identify the phantom structures accurately and possibly automatically in ultrasound images. In the majority of cases 2D ultrasound probes have been calibrated. The advantage of 3D probes is the acquisition of 3D ultrasound volumes out of the box enabling fast calibration approaches based on only one image acquisition. We introduce a new inexpensive and easily to manufacture planes phantom and automatic calibration algorithm for 3D ultrasound probes.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Gronningsaeter A, Kleven A, Ommedal S, et al. SonoWand, an ultrasound-based neuronavigation system. Neurosurgery. 2000;47(6):1373–9.
Beller S, Hünerbein M, Lange T, et al. Image-guided surgery of liver metastases by 3D ultrasound-based optoelectronic navigation. Brit J Surg. 2007;94(7):866–75.
Fenster A, Downey D, Cardinal H. Three-dimensional ultrasound imaging. Phys Med Biol. 2001;46:R67–R99.
Mercier L, Lango T, Lindseth F, et al. A review of calibration techniques for freehand 3-D ultrasound systems. Ultrasound Med Biol. 2005;31(4):449–71.
Hsu P, Prager R, Gee A, et al. Freehand 3D ultrasound calibration: a review. Department of Engineering, University of Cambridge; 2007. 584.
Lange T, Eulenstein S. Calibration of swept-volume 3D ultrasound. In: Houston A, Zwiggelaar R, editors. Proc Med Image Understand Anal. vol. 3; 2002. p. 29–32.
Poon T, Rohling R. Comparison of calibration methods for spatial tracking of a 3-D ultrasound probe. Ultra Med Biol. 2005;31(8):1095–108.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Lange, T., Kraft, S., Eulenstein, S., Lamecker, H., Schlag, P.M. (2011). Automatic Calibration of 3D Ultrasound Probes. In: Handels, H., Ehrhardt, J., Deserno, T., Meinzer, HP., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2011. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-19335-4_36
Download citation
DOI: https://doi.org/10.1007/978-3-642-19335-4_36
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-19334-7
Online ISBN: 978-3-642-19335-4
eBook Packages: Computer Science and Engineering (German Language)