Skip to main content

Model-Based Registration for Motion Compensation during EP Ablation Procedures

  • Conference paper
Biomedical Image Registration (WBIR 2010)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 6204))

Included in the following conference series:

Abstract

Radio-frequency catheter ablation (RFCA) has become an accepted treatment option for atrial fibrillation (Afib). RFCA of Afib involves isolation of the pulmonary veins under X-ray guidance. For easier navigation, two-dimensional X-ray imaging may take advantage of overlay images derived from static pre-operative 3-D data set to add anatomical details which, otherwise, would not be visible under X-ray. Unfortunately, respiratory and cardiac motion may impair the utility of static overlay images for catheter navigation. We developed a system for image-based 2-D motion estimation and compensation as a solution to this problem. It is based on 2-D catheter tracking facilitated by model-based registration of an ellipse-shaped model to fluorosocpic images. A mono-plane or a bi-plane X-ray C-arm system can be used. In the first step of the method, a 2-D model of the catheter device is computed. Respiratory and cardiac motion at the site of ablation is then estimated by tracking the catheter device in fluoroscopic images. The cost function of the registration step is based on the average distance of the model to the segmented circumferential mapping catheter using a distance map. In our experiments, the circumferential catheter was successfully tracked in 688 fluoroscopic images with an average 2-D tracking error of 0.59 mm ± 0.25 mm. Our presented method achieves a tracking rate of 10 frames-per-second.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Cappato, R., Calkins, H., Chen, S.A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.H., Klein, G., Packer, D., Skanes, A.: Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation. Circulation - Journal of the American Heart Association 111, 1100–1105 (2005)

    Google Scholar 

  2. Wazni, O.M., Marrouche, N.F., Martin, D.O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., Gutleben, K., Potenza, E.P.D., Fanelli, R., Raviele, A., Themistoclakis, S., Rossillo, A., Bonso, A., Natale, A.: Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of symptomatic atrial fibrillation: a randomized trial. JAMA 293(21), 2634–2640 (2005)

    Article  Google Scholar 

  3. Zagorchev, et al.: Rapid fusion of 2D x-ray fluoroscopy with 3D multislice CT for image-guided electrophysiology procedures. In: Proceedings of SPIE: Medical Imaging 2007, vol. 6509, p. 65092B (2007)

    Google Scholar 

  4. Sra, J., Narayan, G., Krum, D., Malloy, A., Colley, R., Bhatia, A., Dhala, A., Blanck, Z., Nangia, V., Akhtar, M.: Computed Tomography-Fluoroscopy Image Integration-Guided Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology 18(4), 409–414 (2007)

    Article  Google Scholar 

  5. Ector, J., Buck, S.D., Huybrechts, W., Nuyens, D., Dymarkowski, S., Bogaert, J., Maes, F., Heidüchel, H.: Biplane three-dimensional augmented fluoroscopy as single navigation tool for ablation of atrial fibrillation: Accuracy and clinical value. Heart Rhythm 5(7), 957–964 (2008)

    Article  Google Scholar 

  6. Knecht, S., Skali, H., O’Neill, M.D., Wright, M., Matsuo, S., Chaudhry, G.M., Haffajee, C.I., Nault, I., Gijsbers, G.H.M., Sacher, F., Laurent, F., Montaudon, M., Corneloup, O., Hocini, M., Haissaguerre, M., Orlov, M.V., Jais, P.: Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmia. Europace 10, 931–938 (2008)

    Article  Google Scholar 

  7. Hertrich, P.H.: Practical Radiography - Principles and Applications, 1st edn. Publicis Corporate Publishing (May 2005)

    Google Scholar 

  8. Oppelt, A. (ed.): Imaging Systems for Medical Diagnostics, 2nd edn. Publicis Corporate Publishing (November 2005)

    Google Scholar 

  9. Orlov, M.V., Hoffmeister, P., Chaudhry, G.M., Almasry, I., Gijsbers, G.H.M., Swack, T., Haffajee, C.I.: Three-dimensional rotational angiography of the left atrium and esophagus: a virtual computed tomography scan in the electrophysiology lab? Heart Rhythm 4(1), 37–43 (2007)

    Article  Google Scholar 

  10. Al-Ahmad, A., Wigstrm, L., Sandner-Porkristl, D., Wang, P.J., Zei, P.C., Boese, J., Lauritsch, G., Moore, T., Chan, F., Fahrig, R.: Time-resolved three-dimensional imaging of the left atrium and pulmonary veins in the interventional suite: A comparison between multisweep gated rotational three-dimensional reconstructed fluoroscopy and multislice computed tomography. Heart Rhythm 5(4), 513–519 (2008)

    Article  Google Scholar 

  11. Nölker, G., Gutleben, K.J., Marschang, H., Ritscher, G., Asbach, S., Marrouche, N., Brachmann, J., Sinha, A.M.: Three-dimensional left atrial and esophagus reconstruction using cardiac C-arm computed tomography with image integration into fluoroscopic views for ablation of atrial fibrillation: Accuracy of a novel modality in comparison with multislice computed tomography. Heart Rhythm 5(12), 1651–1657 (2008)

    Article  Google Scholar 

  12. Strobel, N., Meissner, O., Boese, J., Brunner, T., Heigl, B., Hoheisel, M., Lauritsch, G., Nagel, M., Pfister, M., Rührnschopf, E.P., Scholz, B., Schreiber, B., Spahn, M., Zellerhoff, M., Klingenbeck-Regn, K.: Imaging with Flat-Detector C-Arm Systems. In: Reiser, M.F., Becker, C.R., Nikolaou, K., Glazer, G. (eds.) Multislice CT (Medical Radiology / Diagnostic Imaging), 3rd edn., pp. 33–51. Springer, Heidelberg (2009)

    Google Scholar 

  13. Pruemmer, et al.: Cardiac C-arm CT: a unified framework for motion estimation and dynamic CT. IEEE Transactions on Medical Imaging 28(11), 1836–1849 (2009)

    Article  Google Scholar 

  14. Lauritsch, et al.: Towards cardiac C-arm computed tomography. IEEE Transactions on Medical Imaging 28(7), 922–934 (2006)

    Article  Google Scholar 

  15. Brost, A., Liao, R., Hornegger, J., Strobel, N.: 3-D Respiratory Motion Compensation during EP Procedures by Image-Based 3-D Lasso Catheter Model Generation and Tracking. In: Yang, G.-Z., Hawkes, D., Rueckert, D., Noble, A., Taylor, C. (eds.) MICCAI 2009. LNCS, vol. 5761, pp. 394–401. Springer, Heidelberg (2009)

    Chapter  Google Scholar 

  16. Brost, A., Liao, R., Hornegger, J., Strobel, N.: 3D model-based catheter tracking for motion compensation in EP procedures, vol. 7625, 762507. SPIE, San Jose (2010)

    Google Scholar 

  17. Liao, et al.: Location Constraint Based 2D-3D Registration of Fluoroscopic Images of CT Volumes for Image-Guided EP Procedures. In: Proceedings of SPIE: Medical Imaging 2008, vol. 6918, p. 69182T (2008)

    Google Scholar 

  18. Halir, F.: Numerically Stable Direct Least Squares Fitting of Ellipses. In: Proceedings of the 6th Conference in Central Europe on Computer Graphics and Visualization, pp. 253–257 (1998)

    Google Scholar 

  19. Hartley, Z.: Multiple View Geometry in Computer Vision, 2nd edn. Cambridge University Press, Cambridge (2004)

    MATH  Google Scholar 

  20. Fitzgibbon, A., Pilu, M., Fisher, R.B.: Direct least square fitting of ellipses. IEEE Transactions on Pattern Analysis And Machine Intelligence 21(5), 476–480 (1999)

    Article  Google Scholar 

  21. Fitzgibbon, A.W., Fisher, R.B.: A Buyer’s Guide to Conic Fitting. In: BMVC 1995: Proceedings of the 6th British Conference on Machine Vision, Surrey, UK, vol. 2, pp. 513–522. BMVA Press (September 1995)

    Google Scholar 

  22. Bronstein, I.N., Semendjajew, K.A., Musiol, G., Mühlig, H.: Taschenbuch der Mathematik, 5th edn. Verlag Harri Deutsch, Thun und Frankfurt am Main (2001)

    MATH  Google Scholar 

  23. Poole, D.: Linear Algebra - A Modern Introduction, 1st edn. Brooks Cole (2002)

    Google Scholar 

  24. Zwillinger, D.: CRC Standard Mathematical Tables and Formulae, 31th edn. Chapman & Hall/CRC (2002)

    Google Scholar 

  25. Hearn, D., Baker, M.P.: Computer Graphics with OpenGL. Pearson Prentice Hall, London (2004)

    Google Scholar 

  26. Sato, et al.: 3D Multi-Scale Line Filter for Segmentation and Visualization of Curvilinear Structures in Medical Images. Medical Image Analysis 2(2), 143–168 (1998)

    Article  Google Scholar 

  27. Otsu, N.: A Threshold Selection Method from Gray-Level Histograms. IEEE Transactions on Systems, Man, and Cybernetics 9(1), 62–66 (1979)

    Article  MathSciNet  Google Scholar 

  28. Cychosz, J.M.: Efficient Binary Image Thinning using Neighborhood Maps, pp. 465–473 (1994)

    Google Scholar 

  29. Breu, et al.: Linear time Euclidean distance transform algorithms. IEEE Transactions on Pattern Analysis and Machine Intelligence 17, 529–533 (1995)

    Article  Google Scholar 

  30. Ector, et al.: Changes in Left Atrial Anatomy Due to Respiration: Impact on Three-Dimensional Image Integration During Atrial Fibrillation Ablation. Journal of Cardiovascular Electrophysiology 19(7), 828–834 (2008)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Brost, A., Liao, R., Hornegger, J., Strobel, N. (2010). Model-Based Registration for Motion Compensation during EP Ablation Procedures. In: Fischer, B., Dawant, B.M., Lorenz, C. (eds) Biomedical Image Registration. WBIR 2010. Lecture Notes in Computer Science, vol 6204. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-14366-3_21

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-14366-3_21

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-14365-6

  • Online ISBN: 978-3-642-14366-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics