Abstract
A major problem in magnetic resonance imaging (MRI) is the lack of a pulse sequence dependent standardized intensity scale like the Hounsfield units in computed tomography. This affects the post processing of the acquired images as, in general, segmentation and registration methods depend on the observed image intensities. Different approaches dealing with this problem were proposed recently. In this article we will describe and compare five state-of-the-art standardization methods regarding speed, applicability and accuracy. As a quality measure the mean distance and the Kullback-Leibler divergence are considered. For the experiments 28 MRI head volume images, acquired during clinical routine, were used.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Jäger F, Deuerling-Zheng Y, Frericks B, et al. A new method for MRI intensity standardization with application to lesion detection in the brain. In: Kobbelt L, et al, editors. Vision Modeling and Visualization. Köln: Aka GmBH; 2006. p. 269–76.
Nyúl LG, Udupa JK, Zhang X. New variants of a method of MRI scale standardization. IEEE Trans Med Imaging. 2000;19(2):143–50.
Hellier P. Consistent intensity correction of MR images. Proc ICIP. 2003;1:1109–12.
Cox IJ, Roy S, Hingorani SL. Dynamic histogram warping of image pairs for constant image brightness. Proc ICIP. 1995; p. 2366–9.
Weisenfeld N, Warfield S. Normalization of joint image-intensity statistics in MRI using the Kullback-Leibler divergence. Proc IEEE Int Symp Biomed Imaging. 2004;1:101–4.
Jäger F, Nyul L, Frericks B, et al. Whole body MRI intensity standardization. Proc BVM. 2007; p. 459–63.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Bergeest, JP., Jäger, F. (2008). A Comparison of Five Methods for Signal Intensity Standardization in MRI. In: Tolxdorff, T., Braun, J., Deserno, T.M., Horsch, A., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2008. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-78640-5_8
Download citation
DOI: https://doi.org/10.1007/978-3-540-78640-5_8
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-78639-9
Online ISBN: 978-3-540-78640-5
eBook Packages: Computer Science and Engineering (German Language)