Abstract
This paper presents an autostereoscopic three-dimensional (3-D) surgical display with high quality integral videography (IV) rendering algorithm. IV is an animated extension of integral photography, which provides 3-D images without using any supplementary glasses or tracking devices. Despite IV’s many advantages, the quality of its spatial image has thus far been poor. We developed a high quality image rendering method with oversampling technique for enhancing the resolution of elemental IV image and low-pass-filter for smoothing the image. Furthermore, we manufactured a high-resolution IV display for evaluating the feasibility of proposed method. The experimental results show the quality of anti-aliased IV image is improved. We also integrated the developed IV image into image-guided surgery display system. This approach will allow us to acquire the optimum process to produce high quality 3-D image for planning and guidance of minimally invasive surgery.
Chapter PDF
Similar content being viewed by others
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Breedveld, P., Stassen, H.G., Meijer, D.W., Stassen, L.P.S.: Theoretical background and conceptual solution for depth perception and eye-hand coordination problems in laparoscopic surgery. Minim. Invasiv. Ther. 8, 227–234 (1999)
Mitchell, P., Wilkinson, I.D., Griffiths, P.D., Linsley, K., Jakubowski, J.: A stereoscope for image- guided surgery. British Journal of Neurosurgery 16(3), 261–266 (2002)
Seno, H., Mizunuma, M., Nishida, M., Inoue, M., Yanai, A., Irimoto, M.: 3-D-CT stereoscopic imaging in maxillofacial surgery. Journal of Computer Assisted Tomography 23(2), 76–279 (1999)
Backus, B.T., Banks, M.S., van Ee, R., Crowell, J.A.: Horizontal and vertical disparity, eye position, and stereoscopic slant perception. Vision Research 39, 1143–1170 (1999)
Lippmann, M.G.: Epreuves reversibles donnant la sensation du relief. J. de Phys. 7, 4th series 821–825 (1908)
Nakajima, S., Nakamura, K., Masamune, K., Sakuma, I., Dohi, T.: Three-dimensional medical display with computer-generated integral photography. Computerized Medical Imaging and Graphics 25, 235–241 (2001)
Liao, H., Hata, N., Nakajima, S., Iwahara, M., Sakuma, I., Dohi, T.: Surgical Navigation by Autostereoscopic Image Overlay of Integral Videography. IEEE Trans. Inform. Technol. Biomed. 8(2), 114–121 (2004)
Liao, H., Hata, N., Iwahara, M., Sakuma, I., Dohi, T.: An autostereoscopic display system for image-guided surgery using high-quality integral videography with high performance Computing. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2879, pp. 247–255. Springer, Heidelberg (2003)
La Riviere, P.J., Pan, X.C.: Anti-aliasing weighting functions for single-slice helical CT. IEEE Trans. Med. Imag. 21(8), 978–990 (2002)
Yang, J.G., Park, S.T.: An anti-aliasing algorithm for discrete wavelet transform. MECH SYST SIGNAL PR 17, 945–954 (2003)
Mueller, K., Yagel, R., Wheller, J.J.: Anti-aliased three-dimensional cone-beam reconstruction of low-contrast objects with algebraic methods. IEEE Trans. Med. Imag. 18(6), 519–537 (1999)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2004 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Liao, H., Tamura, D., Iwahara, M., Hata, N., Dohi, T. (2004). High Quality Autostereoscopic Surgical Display Using Anti-aliased Integral Videography Imaging. In: Barillot, C., Haynor, D.R., Hellier, P. (eds) Medical Image Computing and Computer-Assisted Intervention – MICCAI 2004. MICCAI 2004. Lecture Notes in Computer Science, vol 3217. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-30136-3_57
Download citation
DOI: https://doi.org/10.1007/978-3-540-30136-3_57
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-22977-3
Online ISBN: 978-3-540-30136-3
eBook Packages: Springer Book Archive