Abstract
Occipitocervical fusion (OCF) is indicated for instability at the craniocervical junction (CCJ). Numerous surgical techniques, which evolved over 90 years, as well as unique anatomic and kinematic relationships of this region present a challenge to the neurosurgeon. The current standard involves internal rigid fixation by polyaxial screws in cervical spine, contoured rods and occipital plate. Such approach precludes the need of postoperative external stabilization, lesser number of involved spinal segments, and provides 95–100% fusion rates. New surgical techniques such as occipital condyle screw or transarticular occipito-condylar screws address limitations of occipital fixation such as variable lateral occipital bone thickness and dural sinus anatomy. As the C0–C1–C2 complex is the most mobile portion of the cervical spine (40% of flexion-extension, 60% of rotation and 10% of lateral bending) stabilization leads to substantial reduction of neck movements. Preoperative assessment of vertebral artery anatomical variations and feasibility of screw insertion as well as visualization with intraoperative fluoroscopy are necessary. Placement of structural and supplemental bone graft around the decorticated bony elements is an essential step of every OCF procedure as the ultimate goal of stabilization with implants is to provide immobilization until bony fusion can develop.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Benzel EC. The cervical spine. Philadelphia: Wolters Kluwer Health/Lippincott Williams & Wilkins; 2012.
Ebraheim NA, Lu J, Biyani A, Brown JA, Yeasting RA. An anatomic study of the thickness of the occipital bone. Spine (Phila Pa 1976). 1996;21(15):1725–9. https://doi.org/10.1097/00007632-199608010-00002.
Roberts DA, Doherty BJ, Heggeness MH. Quantitative anatomy of the occiput and the biomechanics of occipital screw fixation. Spine (Phila Pa 1976). 1998;23(10):1100–7. https://doi.org/10.1097/00007632-199805150-00005.
Yeom JS, Buchowski JM, Kim HJ, Chang BS, Lee CK, Riew KD. Risk of vertebral artery injury: comparison between C1–C2 transarticular and C2 pedicle screws. Spine J. 2013;13(7):775–85. https://doi.org/10.1016/j.spinee.2013.04.005.
Baaj AA, Mummaneni PV, Uribe JS, Vaccaro AR, Greenberg MS. Handbook of spine surgery. New York: Thieme Medical Publishers; 2012.
Lu DC, Roeser AC, Mummaneni VP, Mummaneni PV. Nuances of occipitocervical fixation. Neurosurgery. 2010;66(Suppl 3):141–6. https://doi.org/10.1227/01.NEU.0000365744.54102.B9.
Garrido BJ, Sasso RC. Occipitocervical fusion. Orthop Clin North Am. 2012;43(1):1–9. https://doi.org/10.1016/j.ocl.2011.08.009.
Dick JC, Bourgeault CA. Notch sensitivity of titanium alloy, commercially pure titanium, and stainless steel spinal implants. Spine (Phila Pa 1976). 2001;26(15):1668–72. https://doi.org/10.1097/00007632-200108010-00008.
Kim S, Chang U, Chang J, Kim DH. Posterior stabilization of craniovertebral junction; 2016. doi:https://doi.org/10.1016/B978-1-4160-3367-7.10033-1.
Song GC, Cho KS, Yoo DS, Huh PW, Lee SB. Surgical treatment of craniovertebral junction instability: clinical outcomes and effectiveness in personal experience. J Korean Neurosurg Soc. 2010;48(1):37–45. https://doi.org/10.3340/jkns.2010.48.1.37.
Foerster O. Die Leitungsbahnen Des Schmerzgefuhls Und Die Chirurgischee Behand- Lung Der Schmerzzustande. Berlin: Urbin and Schwarzenberg; 1927.
Hurlbert RJ, Crawford NR, Choi WG, Dickman CA. A biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation. J Neurosurg. 1999;90(1 Suppl):84–90. http://www.ncbi.nlm.nih.gov/pubmed/10413131
Nockels RP, Shaffrey CI, Kanter AS, Azeem S, York JE. Occipitocervical fusion with rigid internal fixation: long-term follow-up data in 69 patients. J Neurosurg Spine. 2007;7(2):117–23. https://doi.org/10.3171/SPI-07/08/117.
Wolfla CE. Anatomical, biomechanical, and practical considerations in posterior occipitocervical instrumentation. Spine J. 2006;6(6 Suppl):225S–32S. https://doi.org/10.1016/j.spinee.2006.09.001.
Pait TG, Al-Mefty O, Boop FA, Arnautovic KI, Rahman S, Ceola W. Inside–outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results. J Neurosurg. 1999;90(1 Suppl):1–7. http://www.ncbi.nlm.nih.gov/pubmed/10413118
Sandhu FA, Pait TG, Benzel E, Henderson FC. Occipitocervical fusion for rheumatoid arthritis using the inside–outside stabilization technique. Spine (Phila Pa 1976). 2003;28(4):414–9. https://doi.org/10.1097/01.BRS.0000048460.58471.DB.
Grob D. Transarticular screw fixation for atlanto-occipital dislocation. Spine (Phila Pa 1976). 2001;26(6):703–7. https://doi.org/10.1097/00007632-200103150-00030.
Uribe JS, Ramos E, Vale F. Feasibility of occipital condyle screw placement for occipitocervical fixation: a cadaveric study and description of a novel technique. J Spinal Disord Tech. 2008;21(8):540–6. https://doi.org/10.1097/BSD.0b013e31816d655e.
Uribe JS, Ramos E, Youssef AS, et al. Craniocervical fixation with occipital condyle screws: biomechanical analysis of a novel technique. Spine (Phila Pa 1976). 2010;35(9):931–8. https://doi.org/10.1097/BRS.0b013e3181c16f9a.
Ahmadian A, Dakwar E, Vale FL, Uribe JS. Occipitocervical fusion via occipital condylar fixation: a clinical case series. J Spinal Disord Tech. 2014;27(4):232–6. https://doi.org/10.1097/BSD.0b013e31825bfeea.
Sawin PD, Traynelis VC, Menezes AH. A comparative analysis of fusion rates and donor-site morbidity for autogeneic rib and iliac crest bone grafts in posterior cervical fusions. J Neurosurg. 1998;88(2):255–65. https://doi.org/10.3171/jns.1998.88.2.0255.
Lindley TE, Dahdaleh NS, Menezes AH, Abode-Iyamah KO. Complications associated with recombinant human bone morphogenetic protein use in pediatric craniocervical arthrodesis. J Neurosurg Pediatr. 2011;7(5):468–74. https://doi.org/10.3171/2011.2.PEDS10487.
Kukreja S, Ambekar S, Sin AH, Nanda A. Occipitocervical fusion surgery: review of operative techniques and results. J Neurol Surg B Skull Base. 2015;76(5):331–9. https://doi.org/10.1055/s-0034-1543967.
Finn MA, Bishop FS, Dailey AT. Surgical treatment of occipitocervical instability. Neurosurgery. 2008;63(5):961–8. https://doi.org/10.1227/01.NEU.0000312706.47944.35.
Martinez-del-Campo E, Turner JD, Kalb S, et al. Occipitocervical fixation. Neurosurgery. 2016;79(4):549–60. https://doi.org/10.1227/NEU.0000000000001340.
Elia M, Mazzara JT, Fielding JW. Onlay technique for occipitocervical fusion. Clin Orthop Relat Res. 1992;280:170–4. http://www.ncbi.nlm.nih.gov/pubmed/1611738
Winegar CD, Lawrence JP, Friel BC, et al. A systematic review of occipital cervical fusion: techniques and outcomes. J Neurosurg Spine. 2010;13(1):5–16. https://doi.org/10.3171/2010.3.SPINE08143.
Visocchi M, Mattogno PP, Signorelli F, Zhong J, Iacopino G, Barbagallo G. Complications in craniovertebral junction instrumentation: hardware removal can be associated with long-lasting stability. Personal experience. Acta Neurochir Suppl. 2017;124:187–94.
Competing Interests
The authors declare that they have no competing interests.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Ethics declarations
No financial support was received for this work.
Rights and permissions
Copyright information
© 2019 Springer International Publishing AG, part of Springer Nature
About this chapter
Cite this chapter
Ashafai, N.S., Visocchi, M., Wąsik, N. (2019). Occipitocervical Fusion: An Updated Review. In: Visocchi, M. (eds) New Trends in Craniovertebral Junction Surgery. Acta Neurochirurgica Supplement, vol 125. Springer, Cham. https://doi.org/10.1007/978-3-319-62515-7_35
Download citation
DOI: https://doi.org/10.1007/978-3-319-62515-7_35
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-62514-0
Online ISBN: 978-3-319-62515-7
eBook Packages: MedicineMedicine (R0)