Abstract
Medical robotics incrementally appears compelling in nowadays surgical work. The research regarding an ideal interaction between physician and computer assistance has reached a first summit with the implementation of commercially available robots (Intuitive Surgical’s® da Vinci ®). Moreover, neurosurgery – and herein spine surgery - seems an ideal candidate for computer assisted surgery. After the adoption of pure navigational support from brain surgery to spine surgery a meanwhile commercially available miniature robot (Mazor Surgical Technologies’ The Spine Assist®) assists in drilling thoracic and lumbar pedicle screws. Pilot studies on efficacy, implementation into neurosurgical operating room work flow proved the accuracy of the system and we shortly outline them. Current applications are promising, and future possible developments seem far beyond imagination. But still, medical robotics is in its infancy. Many of its advantages and disadvantages must be delicately sorted out as the patients safety is of highest priority. Medical robots may achieve a physician’s supplement but not substitute.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Zamorano L, Li Q, Jain S, Kaur G (2004) Robotics in neurosurgery: state of the art and future technological challenges. Int J Med Robot 1:7–22
Barzilay Y, Kaplan L, Libergall M (2008) Robotic assisted spine surgery – a breakthrough or a surgical toy? Int J Med Robot 4:195–196
Nathoo N, Cavusoglu MC, Vogelbaum MA, Barnett GH (2005) In touch with robotics: neurosurgery for the future. Neurosurgery 56:421–433
Barzilay Y, Liebergall M, Fridlander A, Knoller N (2006) Miniature robotic guidance for spine surgery – introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres. Int J Med Robot 2:146–153
Shoham M, Lieberman IH, Benzel EC, Togawa D, Zehavi E, Zilberstein B, Roffman M, Bruskin A, Fridlander A, Joskowicz L, Brink-Danan S, Knoller N (2007) Robotic assisted spinal surgery – from concept to clinical practice. Comput Aided Surg 12:105–115
Sukovich W, Brink-Danan S, Hardenbrook M (2006) Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist. Int J Med Robot 2:114–122
Togawa D, Kayanja MM, Reinhardt MK, Shoham M, Balter A, Friedlander A, Knoller N, Benzel EC, Lieberman IH (2007) Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part 2 – evaluation of system accuracy. Neurosurgery 60:ONS129–139
Lieberman IH, Togawa D, Kayanja MM, Reinhardt MK, Friedlander A, Knoller N, Benzel EC (2006) Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part I – technical development and a test case result. Neurosurgery 59:641–650
Pechlivanis I, Kiriyanthan G, Engelhardt M, Scholz M, Lucke S, Harders A, Schmieder K (2009) Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: first experiences and accuracy of screw placement. Spine (Phila Pa 1976) 34:392–398
Graham JJ (1989) Complications of cervical spine surgery. A five-year report on a survey of the membership of the Cervical Spine Research Society by the Morbidity and Mortality Committee. Spine (Phila Pa 1976) 14:1046–1050
Zeidman SM, Ducker TB, Raycroft J (1997) Trends and complications in cervical spine surgery: 1989–1993. J Spinal Disord 10:523–526
Kelleher MO, McEvoy L, Nagaria J, Kamel M, Bolger C (2006) Image-guided transarticular atlanto-axial screw fixation. Int J Med Robot 2:154–160
Thomale UW, Kneissler M, Hein A, Maetzig M, Kroppenstedt SN, Lueth T, Woiciechowsky C (2005) A spine frame for intra-operative fixation to increase accuracy in spinal navigation and robotics. Comput Aided Surg 10:151–155
Davies B (1996) A discussion of safety issues for medical robots. In: Taylor RH, Lavallée S, Burdeaa GC, Mösges R (eds) Computer-integrated surgery: technology and clinical applications. MIT Press, Cambridge, MA, pp 287–296
Elder MC, Knight JC (1995) Specifying user interfaces for safety-critical medical systems. Medical robotics and computer assisted surgery. Wiley-Liss, New York, pp 148–155
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer-Verlag/Wien
About this chapter
Cite this chapter
Stüer, C., Ringel, F., Stoffel, M., Reinke, A., Behr, M., Meyer, B. (2011). Robotic Technology in Spine Surgery: Current Applications and Future Developments. In: Pamir, M., Seifert, V., Kiris, T. (eds) Intraoperative Imaging. Acta Neurochirurgica Supplementum, vol 109. Springer, Vienna. https://doi.org/10.1007/978-3-211-99651-5_38
Download citation
DOI: https://doi.org/10.1007/978-3-211-99651-5_38
Published:
Publisher Name: Springer, Vienna
Print ISBN: 978-3-211-99650-8
Online ISBN: 978-3-211-99651-5
eBook Packages: MedicineMedicine (R0)