Skip to main content

Biosensors Based on Cantilevers

  • Protocol
Biosensors and Biodetection

Part of the book series: Methods in Molecular Biology™ ((MIMB,volume 504))

Summary

Microcantilevers based-biosensors are a new label-free technique that allows the direct detection of biomolecular interactions in a label-less way and with great accuracy by translating the biointeraction into a nanomechanical motion. Low cost and reliable standard silicon technologies are widely used for the fabrication of cantilevers with well-controlled mechanical properties. Over the last years, the number of applications of these sensors has shown a fast growth in diverse fields, such as genomic or proteomic, because of the biosensor flexibility, the low sample consumption, and the non-pretreated samples required. In this chapter, we report a dedicated design and a fabrication process of highly sensitive microcantilever silicon sensors. We will describe as well an application of the device in the environmental field showing the immunodetection of an organic toxic pesticide as an example. The cantilever biofunctionalization process and the subsequent pesticide determination are detected in real time by monitoring the nanometer-scale bending of the microcantilever due to a differential surface stress generated between both surfaces of the device.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Protocol
USD 49.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 119.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Ziegler, C. (2004) Cantilever-based biosensors.Anal. Bioanal. Chem. 379, 946–959

    CAS  PubMed  Google Scholar 

  2. Alvarez, M., Tamayo, J., Plaza, J.A., Zinoviev, K., Dominguez, C. and Lechuga, L.M. (2006) Dimension dependence of the ther-momechanical noise of microcantilevers.J. App. Phys. 99, 024910

    Article  Google Scholar 

  3. Alvarez, M., Calle, A., Tamayo, J., Lechuga, L.M., Abad, A. and Montoya, A. (2003) Development of nanomechanical biosensors for detection of the pesticide ddt.Biosen. Bio-electron. 18, 649–653

    CAS  Google Scholar 

  4. Mauriz, E., Calle, A., Lechuga, L.M., Quin-tana, J., Montoya, A. and Manclus, J.J. (2006) Real-time detection of chlorpyrifos at part per trillion levels in ground, surface and drinking water samples by a portable surface plasmon resonance immunosensor.Analytica Chimica Acta561, 40–47

    Article  CAS  Google Scholar 

  5. Zhang, J., Lang, H.P., Huber, F., Bietsch, A., Grange, W., Certa, U., Mckendry, R., Guntherodt, H., Hegner, M. and Gerber, C. (2006) Rapid and label-free nano-mechanical detection of biomarker transcripts in human RNA.Nat. Nanotech. 1, 214–220

    Article  CAS  Google Scholar 

  6. Ransley, J.H.T., Watari, M., Sukumaran, D., McKendry, R.A. and Seshia, A.A. (2006) Su8 bio-chemical sensor microarrays.Microelec-tron. Eng.83, 1621–1625

    Article  CAS  Google Scholar 

  7. Zinoviev, K., Dominguez, C., Plaza, J.A., Cadarso, V. and Lechuga, L.M. (2006) A novel optical waveguide microcantilever sensor for the detection of nanomechanical forces.J. Lightwave Technol. V.24(5)(2006) 24, 2132–2140

    Article  Google Scholar 

  8. Lechuga, L.M., Tamayo, J., Álvarez, M., Car-rascosa, L.G., Yufera, A., Doldán, R., Peralías, E., Rueda, A., Plaza, J.A., Zinoviev, K. et al. (2006) A highly sensitive microsystem based on nanomechanical biosensors for genomics applications.Sens. Actuators B118, 2–10

    Article  Google Scholar 

  9. Kumar, S. and Pike, W.T. (2005) Technique for eliminating notching in through-wafer etching.16th MME Micromechanics Eur. Workshop P15, 88–91

    Google Scholar 

  10. Zhang, X.R. and Xu, X.F. (2005) Laser bending for high-precision curvature adjustment of microcantilevers.App. Phys. Lett.86,021114

    Article  Google Scholar 

  11. Plaza, J.A., Zinoviev, K., Villanueva, G., Álvarez, M., Tamayo, J., Domínguez, C. and Lechuga, L.M. (2006) T-shaped microcanti-lever sensor with reduced deflection offset.Appl. Phys. Lett. 89, 094109

    Article  Google Scholar 

  12. Andersson, K., Areskoug, D. and Hardenborg, E. (1999) Exploring buffer space for molecular interactions.J. Molec. Recogn. 12, 310–315

    Article  CAS  Google Scholar 

Download references

Acknowledgments

The authors acknowledge to the European Union (Project Optonanogen, IST-2001-37239). Authors thank Dr. Angel Montoya (Ci2B, University of Valencia, Spain) for the inmunoreagents.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer Science+Business Media, LLC

About this protocol

Cite this protocol

Álvarez, M., Carrascosa, L.G., Zinoviev, K., Plaza, J.A., Lechuga, L.M. (2009). Biosensors Based on Cantilevers. In: Rasooly, A., Herold, K.E. (eds) Biosensors and Biodetection. Methods in Molecular Biology™, vol 504. Humana Press. https://doi.org/10.1007/978-1-60327-569-9_4

Download citation

  • DOI: https://doi.org/10.1007/978-1-60327-569-9_4

  • Publisher Name: Humana Press

  • Print ISBN: 978-1-60327-568-2

  • Online ISBN: 978-1-60327-569-9

  • eBook Packages: Springer Protocols

Publish with us

Policies and ethics