During 1988 the first positive steps were taken to proceed with the design and construction of a neutron capture therapy facility on the High Flux Reactor (HFR) at Petten. The immediate aim is to realise within a short time (summer 1989), an epithermal neutron beam for radiobiological and filter optimisation studies on one of the 10 small aperture horizontal beam tubes. The following summer, a much larger neutron beam, i.e., in cross section and neutron fluence rate, will be constructed on one of the two large beam tubes that replaced the old thermal column in 1984. This latter beam tube faces one whole side of the reactor vessel, extending from a 50 x 40 cm input aperture to a 35 x 35 cm exit hole. The radiotherapeutic facility will be housed here, with the intention to start clinical trials at the beginning of 1991.
This paper describes the present status of the project and includes: a general description of the pertinent characteristics with respect to NCT of the HFR; results of the recently completed preliminary neutron metrology and computer modeling at the input end of the candidate beam tube; the structure and planning of the proposed Work Programme; and the respective direct and indirect participation and collaboration with the Netherlands Cancer Institute and the European Collaboration Group on BNCT.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
R. G. Zamenhof, H. Madoc-Jones, O. K. Harling, and J. A. Bernard, Jr., “A Multidisciplinary Program Leading to a Clinical Trial of Neutron Capture Therapy at Tufts – New England Medical Center and the Massachusetts Institute of Technology,”Strahlenther. Onkol“ 165 (2/3):254 (1989).
H. Roettger et al., “High Flux Materials Testing Reactor Petten, Characteristics of Facilities and Standard Irradiation Devices,” EUR 5700 EN (1986).
F. Stecher-Rasmussen, “Capture Gamma-Ray Spectroscopy and Related Topics,” in Proc. AIP Conf. No. 125, Knoxville, TN (1984).
R. W. A. Kraakman et al., “Neutron Fluence Rate and Neutron Spectrum Measurements in Front of HB 11 and JIB 12. (Part of a Feasibility Study for a BNCT Facility),” ECN-89–06 (1989).
The DOT 3.5 Two-Dimensional Discrete Ordinates Radiation Transport Code,“ Radiation Shielding Information Center, Oak Ridge National Laboratory (1976).
J. F. Breismeister, ed., “MCNP — A General Monte Carlo Code for neutron and photon transport, Version 3A” Los Alamos National Laboratory, LA-7396-M Rev. 2 (1986).
R. G. Fairchild, J. A. Kalef-Ezra, S. Fiarman, L. Wielopolski, J. Hanz, S. Mussolino, and F. Wheeler, “Optimization of an Epithermal Beam for NCI’ at the Brookhaven Medical Research Reactor (BMRR),” Strahlenther. Onkol., 165(2/3):84 (1989).
G. Constantine, J. A. B. Gibson, K. G. Harrison, and R. Schofield, “Harwell Research on Boron Neutron Capture Therapy,” Strahlenther. Onkol., 165(2/3):92 (1989).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1990 Plenum Press, New York
About this chapter
Cite this chapter
Moss, R.L. (1990). Progress Towards Boron Neutron Capture Therapy at the High Flux Reactor Petten. In: Harling, O.K., Bernard, J.A., Zamenhof, R.G. (eds) Neutron Beam Design, Development, and Performance for Neutron Capture Therapy. Basic Life Sciences, vol 54. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-5802-2_13
Download citation
DOI: https://doi.org/10.1007/978-1-4684-5802-2_13
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4684-5804-6
Online ISBN: 978-1-4684-5802-2
eBook Packages: Springer Book Archive