Skip to main content

Pre-Clinical Experience with Full-Wave Inverse-Scattering for Breast Imaging

Sound Speed Sensitivity

  • Conference paper
Acoustical Imaging

Part of the book series: Acoustical Imaging ((ACIM,volume 29))

Abstract

A new transmission ultrasound CT breast scanner (Techniscan Medical Systems, Inc.) was installed for pre-clinical testing at UCSD Medical Center. The scanner utilizes a 3D inverse scattering method to produce whole-breast tomographic images with resolution approximately 1.5 mm in plane, 3.5 mm slice profile and slice spacing of 1 mm. Sound speed accuracy and sensitivity were found to be highly linear (R2=0.99) over the wide range of 1370–1620 m/sec. Attenuation provided a wide image contrast and is able to localize and identify breast lesions. We present representative cases of human subjects enrolled in the pre-clinical study and describe future plans for the system.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. J.F. Greenleaf, S.A. Johnson, W.F. Samayoa, F.A. Duck: Acoustical Imaging (1975).

    Google Scholar 

  2. M.P. André, H.S. Janée, G.P. Otto, et al.: Intl J Imaging Systems Technol 8 (1997) p. 137.

    Article  Google Scholar 

  3. N. Duric, P. Littrup, O. Rama, E. Holsapple: Acoustical Imaging 28 (1997) p. 173.

    Article  Google Scholar 

  4. V.Z. Marmarelis, J. Jeong, D.C. Shin, S. Do: Acoustical Imaging 28 (1997) p. 195.

    Article  Google Scholar 

  5. S.A. Johnson, T. Abbott, R. Bell, M. Berggren, et al.: Acoustical Imaging 28 (2007) p. 147.

    Article  Google Scholar 

  6. J. Wiskin, D.T. Borup, S.A. Johnson, M. Berggren, et al.: Acoustical Imaging 28 (2007) p.183

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer Science+Business Media B.V.

About this paper

Cite this paper

André, M., Barker, C., Sekhon, N., Wiskin, J., Borup, D., Callahan, K. (2008). Pre-Clinical Experience with Full-Wave Inverse-Scattering for Breast Imaging. In: Akiyama, I. (eds) Acoustical Imaging. Acoustical Imaging, vol 29. Springer, Dordrecht. https://doi.org/10.1007/978-1-4020-8823-0_10

Download citation

Publish with us

Policies and ethics