Skip to main content

Application of Liposomes in Non-isotopic Immunoassays: A Review

  • Chapter
Reviews on Immunoassay Technology

Abstract

Liposomes, synthetic phospholipid bilayer vesicles, have been widely used in immunology and microbiology as model membranes, drug carriers and for other purposes. They are also available as analytical tools for immunological reactions. Elegant methods based on complement-dependent liposome immune lysis for studying the interaction of antibodies with various lipid antigens have been devised by several investigators (Kinsky, 1972; Humphries and McConnell, 1974; Six et al., 1973; Smolarsky et al., 1977; Uemura and Kinsky, 1972; Uemura et al., 1980).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Chan, M. W., Tan, C.-T. and Hsia, J. C. (1978). Spin membrane immunoassay; simplicity and specificity. J. Immunol. Methods, 21, 185–195.

    Article  Google Scholar 

  • Cole, F. X., MacDonnell, P., Myles, A., Law, S.-J., Braman, J., Dowden, D., Broeze, J., Clough, K. M. and Vovis, G. F. (1983). EMIA — a novel homogeneous phase enzyme immunoassay. In Avrames, S. (ed.), Immuno enzymatic Techniques, Elsevier Science Publishers, pp. 257–260.

    Google Scholar 

  • Freytag, J. W. and Litchfield, W. J. (1984). Liposome-mediated immunoassay for small haptens (digoxin) independent of complement. J. Immunol. Methods, 70, 133–140.

    Article  Google Scholar 

  • Haga, M., Itagaki, H., Sugawara, S. and Okano, T. (1980). Liposome immunosensor for theophylline. Biochem. Biophys. Res. Comm., 95, 187–188.

    Article  Google Scholar 

  • Hashimoto, Y., Endoh, H. and Sugawara, M. (1984). Chemical methods for the modification of liposomes with proteins or antibodies. In Gregoriadis, G. (ed.), Liposome Technology III; Targeted Drug Delivery and Biological Interaction, CRC Publications, Boca Raton, Florida, pp. 41–49.

    Google Scholar 

  • Hsia, J. C. and Tan, C. T. (1978). Membrane immunoassay: principle and applications of spin membrane immunoassay. Ann. NY. Acad. Sci., 308, 139–146.

    Article  Google Scholar 

  • Huang, L., Huang, A. and Kennel, S. J. (1984). Coupling of antibodies with liposomes. In Gregoriadis, G. (ed.), Liposome Technology III: Targeted Drug Delivery and Biological Interaction, CRC Publications, Boca Raton, Florida, pp. 51–61.

    Google Scholar 

  • Humphries, G. K. and McConnell, H. M. (1974). Immune lysis of liposomes and erythrocyte ghosts loaded with spin label. Proc. Natl. Acad. Sci. USA, 71, 1961–1964.

    Article  Google Scholar 

  • Ishimori, Y., Yasuda, T., Tsumita, T., Notsuri, M., Koyama, M. and Tadakuma, T. (1984). Liposome immune lysis assay (LILA); a simple method to measure anti-protein antibody using protein antigen-bearing liposomes. J. Immunol. Methods, 75, 351–360.

    Article  Google Scholar 

  • Jou, Y.-H. and Bankert, R. B. (1985). Coated cells and their use. U.S. Patent No. 4, 529, 712.

    Google Scholar 

  • Kinsky, S. C. (1972). Antibody-complement interaction with lipid model membrane. Biochem. Biophys. Acta, 265, 1–23.

    Google Scholar 

  • Leserman, L. D., Machy, P. and Barbet, J. (1984). Covalent coupling of monoclonal antibodies and protein A to liposomes; specific interaction with cells in vitro and in vivo. In Gregoriadis, G. (ed.), Liposome Technology III: Targeted Drug Delivery and Biological Interaction, CRC Publications, Boca Raton, Florida, pp. 29–40.

    Google Scholar 

  • Litchfield, W. J., Freytag, J. W. and Adamich, M. (1984). Highly sensitive immunoassays based on use of liposomes without complement. Clin. Chem., 30, 1441–1445.

    Google Scholar 

  • Mandle, R. M. and Wong, Y. N. (1983). Chemiluminescence amplification substrate system for immunochemistry involving microencapsulated fluorescer. U.S. Patent No. 4, 372, 745.

    Google Scholar 

  • Martin, F. J. and Kung, V. T. (1985). Binding characteristics of antibody-bearing liposomes. Ann. N. Y. Acad. Sci., 446, 443–456.

    Article  Google Scholar 

  • Miyai, K. (1985). Advances in nonisotopic immunoassay. Adv. Clin. Chem., 24, 61–110.

    Article  Google Scholar 

  • O’Connell, J. P., Campbell, R. L., Fleming, B. M., Mercolino, T. J., Johnson, M. D. and McLaurin, D. A. (1985). A highly sensitive immunoassay system involving antibody-coated tubes and liposome-entrapped dye. Clin. Chem., 31, 1424–1426.

    Google Scholar 

  • Rosenquist, E. and Vistnes, A. I. (1977). Immune lysis of spin label loaded liposomes incorporating cardiolipin; a new sensitive method for detecting anti-car diolipin antibodies in syphilis serology. J. Immunol. Methods, 15, 147–155.

    Article  Google Scholar 

  • Six, H. R., Uemura, K. and Kinsky, S. C. (1973). Effect of immunoglobulin class and affinity on the initiation of complement-dependent damage to liposomal model membranes sensitized with dinitrophenylated phospholipids. Biochemistry, 12, 4003–4011.

    Article  Google Scholar 

  • Smolarsky, M., Teiltelbaum, D., Sela, M. and Gitler, C. (1977). A simple fluorescent method to determine complement-mediated liposome immune lysis. J. Immunol. Methods, 15, 255–265.

    Article  Google Scholar 

  • Szoka, F. C. (1984). Liposomes with glycolipid-linked antibodies. U.S. Patent No. 4, 483, 929.

    Google Scholar 

  • Szoka, F. C. and Papahadjopoulos, D. (1978). Procedure for preparation of liposomes with large internal aqueous space and high capture by reverse-phase evaporation. Proc. Natl Acad. Sci. USA, 75, 4194–4198.

    Article  Google Scholar 

  • Tan, C. T., Chan, S. W. and Hsia, J. C. (1981). Membrane immunoassay; a spin membrane immunoassay for thyroxine. Methods in Enzymology, 74, 152–161.

    Article  Google Scholar 

  • Uemura, K. and Kinsky, S. C. (1972). Active vs. passive sensitization of liposomes toward antibody and complement by dinitrophenylated derivatives of phosphatidylethanolamine. Biochemistry, 11, 4085–4094.

    Article  Google Scholar 

  • Uemura, K., Yuzawa-Watanabe, M., Kitagawa, N. and Taketomi, T. (1980). Liposome agglutination and liposomal membrane immune-damage assays for the characterization of antibodies to glycosphingolipids. J. Biochem., 87, 1641–1648.

    Google Scholar 

  • Umezawa, Y., Sofue, S. and Takamoto, Y. (1982). Liposome immunoelectrode using glucose enzyme electrode. Denki Kagaka, 50, 107–108.

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Copyright information

© 1988 S. B. Pal and the Contributors

About this chapter

Cite this chapter

Monji, N., Cole, CA., Castro, A. (1988). Application of Liposomes in Non-isotopic Immunoassays: A Review. In: Pal, S.B. (eds) Reviews on Immunoassay Technology. Palgrave Macmillan, London. https://doi.org/10.1007/978-1-349-10318-8_5

Download citation

Publish with us

Policies and ethics