Summary
Modern cementing techniques rely on occluding and sealing of the intramedullary canal in order to generate sufficient pressure to enhance cement penetration. Each plug design should be able to withstand intramedullary pressure levels which can be expected with contemporary cementing procedures and should occlude the canal sufficiently to prevent leakage. Artificial cement restrictors have different abilities to meet these recommendations and the surgeon should carefully choose the right product.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Bannister GC, Miles AW. The influence of cementing technique and blood on the strength of the bone-cement interface. Engl Med 1988; 17(3):131–3
Bean DJ, Hollis JM, Woo SL, Convery FR. Sustained pressurization of polymethylmethacrylate: a comparison of low-and moderate-viscosity bone cements. J Orthop Res 1988; 6(4):580–584
Beim GM, Lavernia C, Convery FR. Intramedullary plugs in cemented hip arthroplasty. J Arthroplasty 1989; 4(2):139–41
Benjamin JB, Gie GA, Lee AJ, Ling RS, Volz RG. Cementing technique and the effects of bleeding. J Bone Joint Surg Br 1987; 69-B(4):620–624
Breusch SJ. Cementing technique in total hip arthroplasty-factors influencing survival of femoral stems. In: Walenkamp GHIM, Murray DW (eds): Bone cements and cementing technique, Springer Verlag, Heidelberg 2001, 53–80
Breusch SJ, Heisel C. Insertion of an expandable cement restrictor reduces intramedullary fat displacement. J Arthroplasty. 2004;19(6):739–44
Breusch SJ, Berghof R, Schneider U, Weiss G, Simank HG, Lukoschek M, Ewerbeck V. Status of cementation technique in total hip endoprostheses in Germany. Z Orthop Ihre Grenzgeb 1999; 137(2):101–7
Bulstra SK, Geesink RG, Bakker D, Bulstra TH, Bouwmeester SJ, van der Linden AJ. Femoral canal occlusion in total hip replacement using a resorbable and flexible cement restrictor. J Bone Joint Surg Br 1996; 78(6):892–8
Charnley J. Acrylic cement in orthopaedic surgery. Edinburgh, London: E&S Livingstone, 1970
Churchill DL, Incavo SJ, Uroskie JA, Beynnon BD. Femoral stem insertion generates high bone cement pressurization. Clin Orthop 2001; 393:335–344
Danter MR, King GJ, Chess DG, Johnson JA, Faber KJ. The effect of cement restrictors on the occlusion of the humeral canal: an in vitro comparative study of 2 devices. J Arthroplasty 2000; 15(1):113–9
Dozier JK, Harrigan T, Kurtz WH, Hawkins C, Hill R. Does increased cement pressure produce superior femoral component fixation? J Arthroplasty 2000; 15(4):488–95
Harris WH. A new approach to total hip replacement without osteotomy of the greater trochanter. Clin Orthop 1975;(106):19–26
Heisel C, Mau H, Borchers T, Muller J, Breusch SJ. [Fat embolism during total hip arthroplasty. Cementless versus cemented—a quantitative in vivo comparison in an animal model]. Orthopäde. 2003;32(3):247–52
Heisel C, Norman T, Rupp R, Pritsch M, Ewerbeck V, Breusch SJ. In vitro performance of intramedullary cement restrictors in total hip arthroplasty. J Biomech 2003; 36(6):835–843
Johnson JA, Johnston D, el Hawary R, Tan SR, Wong LA, Gross M. Occlusion and stability of synthetic femoral canal plugs used in cemented hip arthroplasty. J Appl Biomater 1995; 6(3):213–8
Kallos T, Enis JE, Gollan F, Davis JH. Intramedullary pressure and pulmonary embolism of femoral medullary contents in dogs during insertion of bone cement and a prosthesis. J Bone Joint Surg Am 1974; 56(7):1363–7
Lee AJ, Ling RS. Improved cementing techniques. Instr Course Lect 1981; 30:407–413
Majkowski RS, Bannister GC, Miles AW. The effect of bleeding on the cement-bone interface. An experimental study. Clin Orthop 1994; 299:293–297
Mallory TH. A plastic intermedullary plug for total hip arthroplasty. Clin Orthop 1981;(155):37–40
Maltry JA, Noble PC, Kamaric E, Tullos HS. Factors influencing pressurization of the femoral canal during cemented total hip arthroplasty. J Arthroplasty 1995; 10(4):492–7
Markolf KL, Amstutz HC. In vitro measurement of bone-acrylic interface pressure during femoral component insertion. Clin Orthop 1976; 121:60–66
Markolf KL, Amstutz HC. Penetration and flow of acrylic bone cement. Clin Orthop 1976; 121:99–102
McCaskie AW, Barnes MR, Lin E, Harper WM, Gregg PJ. Cement pressurisation during hip replacement. J Bone Joint Surg Br 1997; 79(3):379–84
McLaughlin JR, Harris WH. A composite plug for occluding the femoral canal prior to cementing a total hip femoral component. Orthop Rev 1994; 23(4):344–6
Mulroy RD, Jr., Harris WH. The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review. J Bone Joint Surg Br 1990; 72-B(5):757–760
Noble PC, Collier MB, Maltry JA, Kamaric E, Tullos HS. Pressurization and centralization enhance the quality and reproducibility of cement mantles. Clin Orthop 1998;(355):77–89
Oh I, Carlson CE, Tomford WW, Harris WH. Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug. J Bone Joint Surg Am 1978; 60(5):608–13
Orsini EC, Byrick RJ, Mullen JB, Kay JC, Waddell JP. Cardiopulmonary function and pulmonary microemboli during arthroplasty using cemented or non-cemented components. The role of intramedullary pressure. J Bone Joint Surg Am 1987; 69(6):822–32
Owens P, Lavernia CJ. Technique for a composite femoral intramedullary plug in cemented hip arthroplasty. J Arthroplasty 1999; 14(3):369–71
Prendergast PJ, Birthistle P, Waide DV, Kumar NV. An investigation of the performance of Biostop G and Hardinge bone plugs. Proc Inst Mech Eng [H] 1999; 213(4):361–5
Prognosis of total hip replacement: Update and validation of results from the Swedish national hip arthroplasty registry. AAOS, Orlando, FL, 2000
Reading AD, McCaskie AW, Barnes MR, Gregg PJ. A comparison of 2 modern femoral cementing techniques: analysis by cement-bone interface pressure measurements, computerized image analysis, and static mechanical testing. J Arthroplasty 2000; 15(4):479–87
Sakkers RJ, Valkema R, de Wijn JR, Lentjes EG, van Blitterswijk CA, Rozing PM. The intramedullary hydraulic pressure tolerance of the human femur. Clin Orthop 1995;(311):183–9
Schneider M, Heisel C, Breusch SJ. [Femoral fissure after cement restrictor implantation]. Z Orthop Ihre Grenzgeb 2003; 141(5):554–556
Song Y, Goodman SB, Jaffe RA. An in vitro study of femoral intramedullary pressures during hip replacement using modern cement technique. Clin Orthop 1994;(302):297–304
Suominen S, Antti-Poika I, Tallroth K, Santavirta S, Voutilainen P, Lindholm TS. Femoral component fixation with and without intramedullary plug. A 6-year follow-up. Arch Orthop Trauma Surg 1996; 115(5):276–9
Thomsen NO, Jensen TT, Uhrbrand B, Mossing NB. Intramedullary plugs in total hip arthroplasty. A comparative study. J Arthroplasty 1992; 7(Suppl):415–8
Tronzo RG, Kallos T, Wyche MQ. Elevation of intramedullary pressure when methylmethacrylate is inserted in total hip arthroplasty. J Bone Joint Surg Am 1974; 56(4):714–8
Wroblewski BM, van der Rijt A. Intramedullary cancellous bone block to improve femoral stem fixation in Charnley low-friction arthroplasty. J Bone Joint Surg Br 1984; 66(5):639–44
Yee AJ, Binnington AG, Hearn T, Protzner K, Fornasier VL, Davey JR. Use of a polyglycolide lactide cement plug restrictor in total hip arthroplasty. Clin Orthop 1999; 364:254–66
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2005 Springer Medizin Verlag Heidelberg
About this chapter
Cite this chapter
Heisel, C., Breusch, S.J. (2005). The Important Role and Choice of Cement Restrictor. In: The Well-Cemented Total Hip Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-28924-0_18
Download citation
DOI: https://doi.org/10.1007/3-540-28924-0_18
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-24197-3
Online ISBN: 978-3-540-28924-1
eBook Packages: MedicineMedicine (R0)