Abstract
Systems for computer aided detection of masses may be used more effectively when they are used for interpretation of suspect abnormalities, instead of solely using them as a prompting aid to avoid oversights. To use CAD algorithms for detection of masses as a decision aid it may be helpful to display suspiciousness of regions computed by CAD. In this paper the quality of probabilities computed for masses by a commercial CAD system is studied in two ways: 1) by comparing standalone performance of the system to that of experienced screening radiologists, and 2) by determining results of independent double reading with CAD. The study involves results of 15 readers who each read 500 mammograms, and two releases of the CAD algorithm. Independent double reading results are obtained by combining probabilities of the CAD system with the reader assessment for each localized finding reported by the reader, and by computing the fraction of cancers localized correctly as a function of false positive referrals. It was found that standalone performance of CAD is less than that of any reader in the study. Nevertheless, it was found that performance improves significantly with independent CAD reading, and that use of an improved CAD algorithm lead to significantly better results of the combined reader with CAD.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Freer, T.W., Ulissey, M.J.: Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. Radiology 220(3), 781–786 (2001)
Cupples, T.E., Cunningham, J.E., Reynolds, J.C.: Impact of computer-aided detection in a regional screening mammography program. AJR Am. J. Roentgenol. 185(4), 944–950 (2005)
Karssemeijer, N., Otten, J.D., Verbeek, A.L., Groenewoud, J.H., de Koning, H.J., Hendriks, J.H., Holland, R.: Computer-aided detection versus independent double reading of masses on mammograms. Radiology 227(1), 192–200 (2003)
Manning, D., Ethell, S., Donovan, T.: Categories of observer error from eye-tracking and afroc data. SPIE Medical Imaging 5372, 90–99 (2004)
Swensson, R.G.: Unified measurement of observer performance in detecting and localizing target objects on images. Med. Phys. 23(10), 1709–1725 (1996)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2006 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Karssemeijer, N. (2006). Use of Prompt Magnitude in Computer Aided Detection of Masses in Mammograms. In: Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds) Digital Mammography. IWDM 2006. Lecture Notes in Computer Science, vol 4046. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11783237_8
Download citation
DOI: https://doi.org/10.1007/11783237_8
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-35625-7
Online ISBN: 978-3-540-35627-1
eBook Packages: Computer ScienceComputer Science (R0)