PET Image Reconstruction: A Robust State Space Approach

  • Conference paper
Information Processing in Medical Imaging (IPMI 2005)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 3565))

Abstract

Statistical iterative reconstruction algorithms have shown improved image quality over conventional nonstatistical methods in PET by using accurate system response models and measurement noise models. Strictly speaking, however, PET measurements, pre-corrected for accidental coincidences, are neither Poisson nor Gaussian distributed and thus do not meet basic assumptions of these algorithms. In addition, the difficulty in determining the proper system response model also greatly affects the quality of the reconstructed images. In this paper, we explore the usage of state space principles for the estimation of activity map in tomographic PET imaging. The proposed strategy formulates the organ activity distribution through tracer kinetics models, and the photon-counting measurements through observation equations, thus makes it possible to unify the dynamic reconstruction problem and static reconstruction problem into a general framework. Further, it coherently treats the uncertainties of the statistical model of the imaging system and the noisy nature of measurement data. Since H  ∞  filter seeks minimum-maximum-error estimates without any assumptions on the system and data noise statistics, it is particular suited for PET image reconstruction where the statistical properties of measurement data and the system model are very complicated. The performance of the proposed framework is evaluated using Shepp-Logan simulated phantom data and real phantom data with favorable results.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Barrett, H.H., Swindell, W.: Radiological Imaging: The Theory of Image For- mation, Detection, and Processing. Academic Press, San Diego (1981)

    Google Scholar 

  2. Fessler, J.A.: Penalized weighted least-squares image reconstruction for positron emission tomography. IEEE Transactions on Medical Imaging 13(2), 290–300 (1994)

    Article  Google Scholar 

  3. Gunn, R.N., Gunn, S.R., Turkheimer, F.E., Aston, J.A.D., Cunningham, V.J.: Tracer Kinetic Modeling via Basis Pursuit. In: Senda, M., Kimura, Y., Herscovitch, P. (eds.) Brain Imaging using PET. Academic Press, London (2002)

    Google Scholar 

  4. Hebert, T., Leahy, R.: A generalized EM algorithm for 3-D Bayesian recon- struction from Poisson data using Gibbs priors. IEEE Transactions on Medical Imaging 8, 194–202 (1989)

    Article  Google Scholar 

  5. Hoffman, E.J., Huang, S.C., Phelps, M.E., Kuhl, D.E.: Quantitation in positron emission computed tomography: 4. effect of accidental coincidences. Journal of Computerized Assisted Tomography 5, 391–400 (1981)

    Article  Google Scholar 

  6. Lewitt, R.M., Matej, S.: Overview of methods for image reconstruction from projections in emission computed tomography. Proceedings of the IEEE 91, 1588–1611 (2003)

    Article  Google Scholar 

  7. Lu, H., Han, G., Chen, D., Li, L., Liang, Z.: A theoretically based pre- reconstructing filter for spatio-temporal noise reduction in gated cardiac SPECT. In: IEEE Nuclear Science Symposium, Lyon, France, October 2000, pp. 141–145 (2000)

    Google Scholar 

  8. Nuyts, J., Michel, C., Dupont, P.: Maximum-likelihood expectation- maximization reconstruction of sinograms with arbitrary noise distribution using NEC-transformations. IEEE Transactions on Medical Imaging 20, 365–375 (2001)

    Article  Google Scholar 

  9. Ollinger, J.M., Fessler, J.A.: Positron emission tomography. IEEE Signal Processing Magazine 14(1), 43–55 (1997)

    Article  Google Scholar 

  10. Qi, J., Leahy, R.M., Cherry, S.R., Chatziioannou, A., Farquhar, T.H.: High resolution 3D Bayesian image reconstruction using the microPET small-animal scanner. Physics in Medicine and Biology 43, 1001–1013 (1998)

    Article  Google Scholar 

  11. Rafecas, M., Boning, G., Pichler, B.J., Lorenz, E., Schwaiger, M., Ziegler, S.I.: Effect of noise in the probability matrix used for statistical reconstruction of PET data. IEEE Transactions on Nuclear Science 51, 149–156 (2004)

    Article  Google Scholar 

  12. Selivanov, V., Picard, Y., Cadorette, J., Rodrigue, S., Lecomte, R.: Detector response models for statistical iterative image reconstruction in high resolution FBI. IEEE Transactions on Nuclear Science 47, 1168–1175 (2000)

    Article  Google Scholar 

  13. Shen, X., Deng, L.: A dynamic system approach to speech enhancement using the H1 filtering algorithm. IEEE Transactions on Speech and Audio Processing 7(4), 391–399 (1999)

    Article  Google Scholar 

  14. Shepp, L.A., Vardi, Y.: Maximum likelihood reconstruction for emission tomog- raphy. IEEE Transactions on Medical Imaging 1, 113–122 (1982)

    Article  Google Scholar 

  15. Veklerov, E., Llacer, J., Hoffman, E.J.: MLE reconstruction of a brain phan- tom using a Monte Carlo transition matrix and a statistical stopping rule. IEEE Transactions on Nuclear Science 35, 603–607 (1988)

    Article  Google Scholar 

  16. Yavuz, M., Fessler, J.A.: New statistical models for randoms precorrected PET scans. In: Duncan, J.S., Gindi, G. (eds.) IPMI 1997. LNCS, vol. 1230, pp. 190–203. Springer, Heidelberg (1997)

    Google Scholar 

  17. Yavuz, M., Fessler, J.A.: Statistical image reconstruction methods for randoms- precorrected PET scans. Medical Image Analysis 2(4), 369–378 (1998)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2005 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Liu, H., Tian, Y., Shi, P. (2005). PET Image Reconstruction: A Robust State Space Approach. In: Christensen, G.E., Sonka, M. (eds) Information Processing in Medical Imaging. IPMI 2005. Lecture Notes in Computer Science, vol 3565. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11505730_17

Download citation

  • DOI: https://doi.org/10.1007/11505730_17

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-26545-0

  • Online ISBN: 978-3-540-31676-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics