Abstract
Background
Distal radius fractures are one of the the most common adult fractures encountered during the clinical practice of an orthopedic surgeon.1,2 Although several methods of treatment are suggested for these fractures, there are still controversies about the best treatment approach in the literature. Volar plating of distal radius fracture is a method of treatment which has become increasingly popular. One of the complications of this technique is flexor tendon rupture. The purpose of this study was to evaluate the protectiveness of complete repair of pronator quadratus muscle against flexor tendon rupture.
Materials and Methods
From September 2010 to September 2012, a consecutive series of 157 patients who were younger than 60 years with unstable distal radius fractures were included in the study. A standard volar approach to the distal radius was carried out. The radial and distal ends of pronator quadratus muscle were meticulously elevated from the radius and after volar plate fixation of the fracture, pronator quadratus muscle was restored to its normal insertion. We achieved full coverage of the plate with this muscle and followed the patients postoperatively.
Results
A total of 135 patients were studied. The mean age of patients was 34 ± 10 years (range 20-60 years). One 55-year-old diabetic female patient with flexor tendon rupture was identified. The flexor pollicis longus tendon had ruptured 16 months after surgery.
Conclusions
Pronator quadratus repair should be done in distal radius fracture to protect flexor tendons.
Similar content being viewed by others
References
Cherubino P, Bini A, Marcolli D. Management of distal radius fractures: Treatment protocol and functional results. Injury 2010;41:1120–6.
Caesar B. Epidemiology of adult fractures: A review. Injury 2006;37:691–7.
Ng C, McQueen M. What are the radiological predictors of functional outcome following fractures of the distal radius? J Bone Joint Surg Br 2011;93:145–50.
Brown EN, Lifchez SD. Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture: Pronator quadratus plate coverage may not adequately protect tendons. Eplasty 2011;11:461–6.
Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 2003;27:1–6.
White BD, Nydick JA, Karsky D, Williams BD, Hess AV, Stone JD. Incidence and clinical outcomes of tendon rupture following distal radius fracture. J Hand Surg 2012;37:2035–40.
Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007;21:316–22.
Soong M, van Leerdam R, Guitton TG, Got C, Katarincic J, Ring D. Fracture of the distal radius: Risk factors for complications after locked volar plate fixation. J Hand Surg 2011;36:3–9.
Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg 2011;93:328–35.
Zlotolow DA, Raven II. RB. Avoiding complications with volar plating of distal radial fractures. Curr Orthop Pract 2012;23:300–4.
Tanaka Y, Aoki M, Izumi T, Fujimiya M, Yamashita T, Imai T. Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge. J Hand Surg 2011;36:1790–7.
Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg 2000;5:103–12.
Swigart CR, Badon MA, Bruegel VL, Dodds SD. Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: A Prospective Clinical Cohort Study. J Hand Surg 2012;37:1868–73.
Lafontaine M, Hardy D, Delince P. Stability assessment of distal radius fractures. Injury 1989;20:208–10.
Altissimi M, Mancini G, Azzara A, Ciaffoloni E. Early and late displacement of fractures of the distal radius. Int Orthop 1994;18:61–5.
McConkey MO, Schwab TD, Travlos A, Oxland TR, Goetz T. Quantification of pronator quadratus contribution to isometric pronation torque of the forearm. J Hand Surg 2009;34:1612–7.
Gofton WT, Gordon KD, Dunning CE, Johnson JA, King GJ. Soft-tissue stabilizers of the distal radioulnar joint: An in vitro kinematic study. J Hand Surg 2004;29:423–31.
Gordon KD, Dunning CE, Johnson JA, King GJ. Influence of the pronator quadratus and supinator muscle load on DRUJ stability. J Hand Surg 2003;28:943–50.
Schneppendahl J, Windolf J, Kaufmann RA. Distal radius fractures: Current concepts. J Hand Surg 2012;37:1718–25.
Nunley JA, Rowan PR. Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the π plate on the volar surface of the distal radius. J Hand Surg 1999;24:1279–80.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tahririan, M.A., Javdan, M. & Motififard, M. Results of pronator quadratus repair in distal radius fractures to prevent tendon ruptures. IJOO 48, 399–403 (2014). https://doi.org/10.4103/0019-5413.136275
Published:
Issue Date:
DOI: https://doi.org/10.4103/0019-5413.136275