Abstract
The residual magnetic field strength inside a pipeline after testing by a magnetic flaw detector is calculated. A portable device for demagnetizing local joint-pipe sections in carrying out repair-welding works is proposed.
Similar content being viewed by others
References
Bezlyud'ko, G.Ya, Volokhov, S.A., and Muzhitskii, V.F., Technology of Demagnetization of Large-Diameter Pipes for Upgrading the Quality of Welding Works in Main Pipelines, In: 9-ya mezhdunarodnaya delovaya vstrecha “Diagnostika-99”. T. 2. Diagnostika lineinoi chasti magistral'nykh truboprovodov (9th International Workshop “Diagnostics-99”. Vol. 2. Diagnostics of the Linear Part of Main Pipelines), Sochi: 1999, April.
Dobrodeev, P.I., Volokhov, S.A., and Mamin, S.I., Experience of Demagnetization of Pipes in Main Pipelines, In: 3-ya mezhdunarodnaya konferentsiya “Diagnostika truboprovodov” (3rd International Conference “Pipeline Diagnostics”), Moscow, May 21-26, 2001.
Nerazrushayushchii kontrol' i diagnostika. Spravochnik (Nondestructive Testing and Diagnostics. Handbook), Klyuev, V.V., Sosnin, F.R., Filinov, V.I. et al. (Eds.), Moscow: Mashinostroenie, 1995.
Marinchuk, M.E. and Savorskii, I.S., Investigation of Magnetostatic Fields for Certain Models of Surface Flaws, Defektoskopiya, 1969, no. 6, pp. 63–69.
Muzhitskii, V.F., Model of a Surface Flaw and Calculation of Topography of its Magnetostatic Field, Defektoskopiya, 1987, no. 3, pp. 24–30.
Muzhitskii, V.F. and Karabchevskii, V.A., Magnetic Field Analysis for Arched Surface Cracks, Nondest. Test. Eval., vol. 6, pp. 287–296.
Zagidulin, R.V., Calculation of the Residual Magnetic Field of a Continuity Flaw in a Ferromagnetic Piece. 1. Magnetic Field inside a Ferromagnetic, Defektoskopiya, 1998, no. 10, pp. 21–32.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Zagidulin, R.V., Muzhitskii, V.F. Estimation of the Residual Magnetic Field Strength Inside a Pipeline after Testing by a Magnetic Flaw Detector. Russian Journal of Nondestructive Testing 39, 549–552 (2003). https://doi.org/10.1023/B:RUNT.0000012794.98758.df
Issue Date: