Abstract
Case: We present a case of 19-year-old male patient with right sided comminuted metadiaphyseal distal femur fracture. Fixation was done using distal femur condylar locking plate. Washers were used with the screws to shimming the plate to achieve the coronal alignment and prevent stress over the screws. 2-year follow-up shows good alignment, radiological union and functional outcome without any complications. “Shimming” a locking plate with washers helps to achieve the better coronal alignment in comminuted metadiaphyseal distal femur fractures with coronal malalignment. It reduces the stress over screws and prevents implant-related complications.
Similar content being viewed by others
References
Natarajan, M. V., Nagaraj, C., Selvaraj, R., Pasupathy, B., Raj, A. V., & Sankarlingam, P. (2006). Management of periarticular fractures of long bones of the lower extremity by hybrid external fixation. Indian Journal of Orthopaedics., 40(3), 177.
Bellabarba, C., Ricci, W. M., & Bolhofner, B. R. (2002). Indirect reduction and plating of distal femoral nonunions. Journal of Orthopaedic Trauma, 16(5), 287–296.
Xing, W., Lin, W., Dai, J., Kong, Z., Wang, Y., Sun, L., Zhang, Z., & Sun, L. (2018). Clinical effect of locking compression plate via posterolateral approach in the treatment of distal femoral fractures: a new approach. Journal of Orthopaedic Surgery and Research, 13(1), 57.
Higgins, T. F. (2007). “Shimming” a locking plate with washers to correct axial alignment. Journal of Orthopaedic Trauma, 21(6), 400–403.
Pascarella, R., Bettuzzi, C., Bosco, G., Leonetti, D., Dessi, S., Forte, P., & Amendola, L. (2014). Results in treatment of distal femur fractures using polyaxial locking plate. Strategies in Trauma and Limb Reconstruction, 9(1), 13–18.
Schuetz, M., Müller, M., Krettek, C., Höntzsch, D., Regazzoni, P., Ganz, R., & Haas, N. (2001). Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study results of a clinical study with special emphasis on difficult cases. Injury, 1(32), 48–54.
Bishop, J. A., Campbell, S. T., Graves, M. L., & Gardner, M. J. (2020). Contouring plates in fracture surgery: Indications and pitfalls. JAAOS-Journal of the American Academy of Orthopaedic Surgeons, 28(14), 585–595.
Funding
None.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
Authors declare no conflict of interest.
Ethical approval
Ethical approval from the institutional review board was not required for this study.
Informed consent
Written informed consent was obtained from the patient for publication of this article.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Gawhale, S.K., Kantharaju, H., Kumar, G.S.P. et al. “Shimming a Plate” Technique to Correct the Coronal Malalignment in Metadiaphyseal Distal Femur Fracture: Case Report. JOIO 56, 501–504 (2022). https://doi.org/10.1007/s43465-021-00507-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s43465-021-00507-1