Abstract

Case: We present a case of 19-year-old male patient with right sided comminuted metadiaphyseal distal femur fracture. Fixation was done using distal femur condylar locking plate. Washers were used with the screws to shimming the plate to achieve the coronal alignment and prevent stress over the screws. 2-year follow-up shows good alignment, radiological union and functional outcome without any complications. “Shimming” a locking plate with washers helps to achieve the better coronal alignment in comminuted metadiaphyseal distal femur fractures with coronal malalignment. It reduces the stress over screws and prevents implant-related complications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Natarajan, M. V., Nagaraj, C., Selvaraj, R., Pasupathy, B., Raj, A. V., & Sankarlingam, P. (2006). Management of periarticular fractures of long bones of the lower extremity by hybrid external fixation. Indian Journal of Orthopaedics., 40(3), 177.

    Article  Google Scholar 

  2. Bellabarba, C., Ricci, W. M., & Bolhofner, B. R. (2002). Indirect reduction and plating of distal femoral nonunions. Journal of Orthopaedic Trauma, 16(5), 287–296.

    Article  Google Scholar 

  3. Xing, W., Lin, W., Dai, J., Kong, Z., Wang, Y., Sun, L., Zhang, Z., & Sun, L. (2018). Clinical effect of locking compression plate via posterolateral approach in the treatment of distal femoral fractures: a new approach. Journal of Orthopaedic Surgery and Research, 13(1), 57.

    Article  Google Scholar 

  4. Higgins, T. F. (2007). “Shimming” a locking plate with washers to correct axial alignment. Journal of Orthopaedic Trauma, 21(6), 400–403.

    Article  Google Scholar 

  5. Pascarella, R., Bettuzzi, C., Bosco, G., Leonetti, D., Dessi, S., Forte, P., & Amendola, L. (2014). Results in treatment of distal femur fractures using polyaxial locking plate. Strategies in Trauma and Limb Reconstruction, 9(1), 13–18.

    Article  CAS  Google Scholar 

  6. Schuetz, M., Müller, M., Krettek, C., Höntzsch, D., Regazzoni, P., Ganz, R., & Haas, N. (2001). Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study results of a clinical study with special emphasis on difficult cases. Injury, 1(32), 48–54.

    Article  Google Scholar 

  7. Bishop, J. A., Campbell, S. T., Graves, M. L., & Gardner, M. J. (2020). Contouring plates in fracture surgery: Indications and pitfalls. JAAOS-Journal of the American Academy of Orthopaedic Surgeons, 28(14), 585–595.

    Article  Google Scholar 

Download references

Funding

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. Kantharaju.

Ethics declarations

Conflict of interest

Authors declare no conflict of interest.

Ethical approval

Ethical approval from the institutional review board was not required for this study.

Informed consent

Written informed consent was obtained from the patient for publication of this article.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gawhale, S.K., Kantharaju, H., Kumar, G.S.P. et al. “Shimming a Plate” Technique to Correct the Coronal Malalignment in Metadiaphyseal Distal Femur Fracture: Case Report. JOIO 56, 501–504 (2022). https://doi.org/10.1007/s43465-021-00507-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s43465-021-00507-1

Keywords

Navigation