Results are presented from a metrological study of the field of the experimental channel of the OR research reactor (an experimental facility at the NRC Kurchatov Institute) with a power of 0.1–300 kW. Empirical dependences are obtained for the contribution of the absorbed dose of gamma radiation to the absorbed dose rate over the entire irradiation time as the OR reactor power is raised and lowered in the steady state. Based on these results, a preliminary calculation can be made of the absorbed dose and absorbed dose rate of the gamma radiation. The experimental channel of the OR reactor was certified on the basis of the metrological studies in terms of the absorbed dose rate of gamma radiation as a specialized source of gamma radiation combined spatially with a model reference neutron field in this channel. The specialized source is intended for calibration of special-purpose measurement instrumentation and for testing the radiation resistance of products operating in the mixed gamma-neutron radiation fields of nuclear reactors.
Similar content being viewed by others
References
V. G. Madeev, E. I. Uksusov, I. V. Cheshigin, et al., "Irradiation installation OR-M for researches of equipment radiation resistance to neutron and gamma radiation influence of nuclear reactor," Vopr. At. Nauki Tekhn. Ser. Fiz. Rad. Vozd. Radioelektr. App., No. 4, 77–79 (2013).
V. D. Sevast’yanov, S. A. Nikolaev, I. E. Somov, et al., "Neutron fields of research reactors for calibration of detectors inside reactors at nuclear power plants," At. Energ., 100, No. 2, 97–107 (2006).
V. D. Sevast’yanov, A. E. Volkov, N. V. Petrunin, et al., "High-intensity neutron fields for calibrating the detectors of a standard control system for high-power nuclear reactors," Prib. Tekhn. Experim., 46, No. 6, 13–22 (2003).
V. V. Generalova, A. P. Zhanzhora, A. S. Koshelev, and A. T. Narozhnyi, Izmer. Tekhn., No. 1, 35–39 (2010).
M. A. Mussaeva, E. M. Ibragimova, and M. I. Muminov, "Dosimetry of gamma-radiation of reactor with fused quartz," At. Energ., 100, No. 3, 216–220 (2006).
A. Delgado, "Mixed field dosimetry," 10th Int. Congr. of the International Radiation Protection Association IRPA-10, https://www.irpa.net/irpa10/pdf/E12.pdf, acc. 07.03.2020.
B. A. Briskman and R. B. Novgorodtsev, "Dosimetry of mixed n-γ radiation," At. Energ., 36, No. 1, 30–49 (1974).
F. Trompier, P. Fattibene, D. Tikunov, et al., Rad. Prot. Dosim., 110, No. 1-4, 437–442 (2004), https://doi.org/10.1093/rpd/nch225.
V. V. Aleikin, V. V. Generalova, A. A. Gromov, and O. I. Kovalenko, Izmer. Tekhn., No. 7, 10–13 (2019), 10.32446/0368-1025it.2019-7-10-13.
A. S. Doinikov, A. P. Zhanzhora, O. I. Kovalenko, et al., "Analysis of the existing regulatory framework to ensure the uniformity of measurement for reference materials and development of proposals for its harmonization with international law," Alm. Sovr. Metrol., No. 13, 145–175 (2018).
S. V. Vorontsov, A. S. Koshelev, V. Kh. Khoruzhi, et al., "A multicomponent reference field of radiation effect at a research reactor with a test system function," Alm. Sovr. Metrol., No. 5. pp. 11–20 (2015).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Izmeritel'naya Tekhnika, No. 3, pp. 53–57, March 2021.
Rights and permissions
About this article
Cite this article
Gromov, A.A., Zhanzhora, A.P. & Shikalov, V.F. Certification of a Specialized Source of Gamma Radiation Spatially Combined with a Model Reference Neutron Radiation Field. Meas Tech 64, 244–249 (2021). https://doi.org/10.1007/s11018-021-01925-1
Received:
Accepted:
Published:
Issue Date: