Questions related to metrological assurance of the thermomechanical indicators of pre-explosive concentrations of hydrocarbons in the air using as an example the STM-30-50 plant are considered. Causes for the appearance of an additional error in these measuring instruments and methods of eliminating (decreasing) this error are analyzed.
Similar content being viewed by others
References
RD BT 39-0147171-003–88, Requirements for Installation of Sensors of Stationary Gas Indicators in Production Rooms and at Outdoor Sites of Enterprises in the Petroleum and Gas Industry.
Resolution of State Mining Technical Inspection Agency of the Russian Federation No. 54 (June 5, 2003). Safety Rules for Gas Processing Plants and Factories, www.zaki.ru, accessed June 8, 2012.
STM-30-50 Indicator, www.technoline.ru>catalog/product/1472, accessed June 8, 2012.
N. B. Vargaftik, Manual on Thermophysical Properties of Gases and Liquids [in Russian], Nauka, Moscow (1972).
TU-GAZ–86, Requirements on Installation of Indicators and Gas Analyzers.
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Izmeritel’naya Tekhnika, No. 10, pp. 70–73, October, 2012.
Rights and permissions
About this article
Cite this article
Beloshitskii, A.P., Gavrilov, L.A. Measurement of the pre-explosive concentrations of hydrocarbons in the air of the working zone of the processing plants of oil-refining enterprises. Meas Tech 55, 1224–1228 (2013). https://doi.org/10.1007/s11018-012-0112-y
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11018-012-0112-y