Rain depolarization and attenuation measurements at 11.7, 19.04, and 28.56 GHz : A description of the experiment and some preliminary 11.7 GHz results

  • Published:
Annales des Télécommunications Aims and scope Submit manuscript

Abstract

The authors are investigating rain depolarization and attenuation at 11.7 GHz using the CTS space craft downlink, and at 19.04 and 28.56 GHz using the COMSTAR satellite. The CTS transmitter is righthand circularly polarized while the COMSTAR polarization is linear. Operations at 11.7 GHz began in late May, 1976, and data collection at the higher frequencies began in May, 1977. In each case the earth receiver measures the amplitudes and relative phases of the copolarized and cross-polarized signal components. These will be correlated with data from a network of terrestrial weather instruments and a weather radar. This paper describes the receiving equipment used and presents a summary of the 11.7 GHz data collected thus far. Several rain events with fades in excess of 30 dB at 11.7 GHz are included; these were accompanied by sharp reductions in the cross polarization isolation. The statistical characteristics of 11.7 GHz attenuation and depolarization are also described.

Analyse

Les auteurs étudient l’affaiblissement et la dépolarisation dus à la pluie en utilisant la liaison descendante du satellite CTS à 19,04 et 28,56 GHz. Pour ce faire, ils utilisent les balises des satellites COMSTAR. L’émetteur du CTS est polarisé circulairement à droite alors que la polarisation COMSTAR est linéaire. Les opérations à 11,7 GHz ont commencé à la fin de mai 1976 et à partir de mai 1977 on a obtenu des données à plus haute fréquence. Dans chaque cas le récepteur terrestre mesure les amplitudes et la phase relative des composantes des polarisations parallèles et croisées. Ceci sera corrélé avec les données venant d’un réseau terrestre d’appareils et d’un radar météorologique. Cet article décrit l’équipement de réception utilisé et présente un résumé des données recueillies jusqu’à ce jour à 11,7 GHz, y compris plusieurs événements de pluie avec des évanouissements dépassant 30 dB à 11 GHz. Ceux-ci ont été accompagnés de réductions brutales de l’isolation par polarisation croisée. On décrit également les caractéristiques statistiques de l’affaiblissement et de la dépolarisation à 11,7 GHz.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Morrison (J. A.),Cross (M. J.). Scattering of a plane electromagnetic wave by axisymmetric raindrops.Bell Syst. tech. J., U. S. A. (juil. 1974),53, n∘ 6, pp. 955–1 019.

    Google Scholar 

  2. Oguchi (T.),Hosoya (Y.). Scattering properties of oblate raindrops and cross polarization of radio waves due to rain (Part II). Calculations at microwave and millimeter wave regions.J. Radio Res. Lab., Jap. (1974),21, n∘ 105, pp. 191–259.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

The research described in this paper is supported by NASA and the U.S. Defense Communications Agency under Contract NAS5-22577.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bostian, C.W., Holt, S.B., Kauffman, S.R. et al. Rain depolarization and attenuation measurements at 11.7, 19.04, and 28.56 GHz : A description of the experiment and some preliminary 11.7 GHz results. Ann. Télécommunic. 32, 519–523 (1977). https://doi.org/10.1007/BF03003506

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03003506

Keywords

Navigation