Skip to main content
Log in

Formation and Emission of Chlorinated by-Products from a Bench-Scale Packed-Bed Odor Scrubber

  • Published:
Water, Air, and Soil Pollution Aims and scope Submit manuscript

Abstract

The phenomenon of chlorinated byproduct formation and their possible emission from odor control systems employing chlorine scrubbing solutions was evaluated. Experiments with hypochlorite scrubbing solution were performed with a bench-scale, single-stage, packed-bed odor scrubber to explore the potential for generating toxic air contaminants (TACs) such as chloroform in full-scale operating units. Known concentrations of a mixture of volatile organic compounds (VOCs) commonly found in wastewater were introduced at realistic field concentrations in an airstream to the inlet of a counter-current packed-tower operated with different scrubbing solutions. Formation of TACs was observed in the scrubbing solution under low-, neutral- and high-pH conditions. The addition of a mixture of VOCs: acetone, methylethylketone, formaldehyde and acetaldehyde, produced chloroform under neutral to high pH conditions. Under low-to neutral-pH conditions, toluene and chlorophenol produced chlorotoluenes and chlorophenols as reaction byproducts. Under the bench-scale unit’s operating conditions, trace levels of the reaction byproducts formed were stripped from the re-circulated scrubber solution into the outlet gas. Based on the bench-scale observations and a quasi-steady-state, first-order reaction model applied to the scrubber reservoir and packed tower system, scrubber solution residence time in the liquid reservoir is hypothesized to be an important operating parameter affecting TAC formation in full-scale hypochlorite-based, packed-tower, odor control units.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Card, T. R.: 1989, ‘Volatile organic compound removal in packed towers and atomized mist odor scrubbing systems’, in Proceedings of the 62nd Annual Water Pollution Control Federation Conference, San Francisco, CA, U.S.A.

  • Cheremisinoff, P. N., Bethea, R. M., Hellman, T. M. and Lauren, O. B.: 1975, ‘Techniques for industrial odor control’, Pollut. Eng. 7, 24.

    CAS  Google Scholar 

  • EBMUD.: 1992, Annual Progress Report-Control and Production of Toxic Air Emissions by POTW Odor Control Equipment, WERF Project RFP No WERF 91-VOC-2, East Bay Municipal Utility District, Oakland, CA, U.S.A.

  • Howard, P.: 1990, Handbook of Environmental Fate and Exposure Data for Organic Chemical, vol. II, Lewis Publishers, Chelsea, MI.

    Google Scholar 

  • Lozovik, A. and Rothermel, J.: 1998, Acetaldehyde Determination in Scrubber Solution, MWRA Central Laboratory Internal Report.

  • Murphy, A., Rowley, L. and Moody, C.: 1993, ‘Dilute aqueous formaldehyde oxidation with hypochlorous acid’, Desalination 91, 199.

    Article  CAS  Google Scholar 

  • Myslinski, T., Basu, S., Rhode, S., Hunt, G. and Shilinsky, K.: 1999, ‘Fate of air toxics and VOC’s in the odor control scrubbers at the Deer island treatment plant’, in Proceedings of the 92nd Annual Meeting of the Air and Waste Management Association, St. Louis, Missouri, U.S.A.

  • Overcamp, T. J.: 1999, ‘Modeling oxidizing scrubbers for odor control’, Environ. Sci. Technol. 33, 155.

    Article  CAS  Google Scholar 

  • Seinfeld, J. H.: 1986, Atmospheric Chemistry and Physics of Air Pollution, Wiley, New York, U.S.A, pp. 201–20.

    Google Scholar 

  • Sereno, D. J., MacGinley, C. T., Harrison, D. S. and Haug, R. T.: 1993, ‘Multi-stage control of air emissions from dewatered sludge storage’, Water Environ. Res. 65, 66.

    CAS  Google Scholar 

  • Shahalam, A. B. M.: 1982, ‘Scrubbing odor from wastewater treatment’, J. Environ. Eng. Div. ASCE 108, 785.

    CAS  Google Scholar 

  • Van Durme, G. P., Rinnert, S. A., Clark, J. H., Mohamed, F. and Furuta, S. L.: 1992, ‘Removal of reactive organic gases and odor in a packed tower scrubber’, in Proceedings of the 85th Annual Meeting of the Air and Waste Management Association, Kansas city, Missouri, U.S.A.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chi-Wen Lin.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lin, CW., Chang, D.P.Y. Formation and Emission of Chlorinated by-Products from a Bench-Scale Packed-Bed Odor Scrubber. Water Air Soil Pollut 162, 19–35 (2005). https://doi.org/10.1007/s11270-005-5990-z

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11270-005-5990-z

Keywords

Navigation