Abstract
An open metal freezing-point cell design has been developed in the Laboratory of Metrology and Quality. According to our design, a zinc cell was successfully assembled. The paper presents the needed parts for the cell, the cleaning process, and sealing of the cell. The assembled cell was then evaluated by comparison with two commercial closed zinc cells of different manufacturers. The freezing plateaus of the cells were measured, and a direct cell comparison was made. It was shown that the assembled open cell performed better than the used closed cell and was close to the brand new closed cell. The nominal purity of the zinc used for the open cell was 7 N, but the freezing plateau measurement suggests a higher impurity concentration. It was assumed that the zinc was contaminated to some extent during the process of cutting as its original shape was an irregular cylinder. The uncertainty due to impurities for the assembled cell is estimated to be 0.3 mK. Furthermore, the immersion profile and the pressure coefficient were measured. Both results are close to their theoretical values.
Similar content being viewed by others
References
H. Preston-Thomas, Metrologia 27, 3, 107 (Erratum) (1990)
Working Group 3 of the Consultative Committee for Thermometry (CCT-WG3), CCT/08-19rev: Uncertainties in the Realisation of the SPRT Subranges of the ITS-90 (Bureau International des Poids et Mesures-BIPM, Sèvres, France, 2009), http://www.bipm.org/cc/CCT/Allowed/24/D19_rev_WG3_Doc_rev_10July2009.pdf. Accessed 7 May 2014
J.V. Widiatmo, K. Harada, K. Yamazawa, M. Arai, Metrologia 43, 561 (2006)
C. Yaokulbodee, U. Norranim, J.V. Widiatmo, K. Yamazawa, J. Tamba, Int. J. Thermophys. 31, 1849 (2010)
V. Batagelj, J. Bojkovski, J. Drnovšek, IET Sci. Meas. Technol. 2, 100 (2008)
E. Renaot, Y. Hermier, M. Valin, G. Bonnier, Report to the CCT on Key Comparison EUROMET T-K3 (Euromet Project 552), Comparison of the Realisations of the ITS-90 from 83,805 8 K to 692, 677 K (Bureau International des Poids et Mesures-BIPM, Sèvres, France, 2006), http://kcdb.bipm.org/appendixB/appbresults/euromet.t-k3/euromet.t-k3_final_report.pdf. Accessed 7 May 2014
G.F. Strouse, CCT/03-19, NIST Methods of Estimating the Impurity Uncertainty Component for ITS-90 Fixed-Point Cells from the Ar TP to the Ag FP (Bureau International des Poids et Mesures-BIPM, Sèvres, France, 2003), http://www.bipm.org/cc/CCT/Allowed/22/CCT03-19.pdf. Accessed 7 May 2014
M. Hiti, J. Bojkovski, V. Batagelj, J. Drnovšek, Meas. Sci. Technol. 16, 2375 (2005)
S. Rudtsch, A. Aulich, C. Monte, in Proceedings of Ninth International Temperature Symposium, Los Angeles, Temperature: Its Measurement and Control in Science and Industry, vol. 8, ed. by C.W. Meyer, A.I.P. Proceedings, 1552 (AIP, Melville, NY, 2013), pp. 265–270
Acknowledgments
This work was partially supported by Ministry of Economic Development and Technology, Metrology Institute of Republic Slovenia in scope of contract 6401-18/2008/70 for national standard laboratory for the field of thermodynamic temperature and humidity.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Žužek, V., Batagelj, V., Drnovšek, J. et al. Open Zinc Freezing-Point Cell Assembly and Evaluation. Int J Thermophys 35, 1147–1155 (2014). https://doi.org/10.1007/s10765-014-1669-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10765-014-1669-2