We focus on research to develop a compact human blood sampling device used for the Self Monitoring of Blood Glucose (SMBG). The SMBG comprises: (1) an indentation system using a shape memory alloy (SMA) actuator to force a microneedle through the skin; (2) a micro electrical pumping system to extract blood using a bimorph type piezoelectric microactuator; (3) a biosensor using an enzyme such as glucose oxidase (GOx) to detect and evaluate the amount of glucose in extracted blood. A titanium microneedle the same size as a female mosquito's labium (60 μm outer diameter, 25 μm inner diameter) was produced by the sputter deposition method. The mechanical design of the device was based upon the mosquito's blood sampling mechanism. The blood extraction system worked well. We measured the performance of the principal components: the indentation load for a microneedle of external diameter 100 μm was found to be 0.1 N. The pumping system has an extraction speed of about 2 μl/min for whole blood. This is similar to that achieved by the mosquito.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • J.H. Barbee and G.R. Cokelet, Macrovascular Research 3 1, 6–16 (1971).

    Google Scholar 

  • T. Ikeshoji, Mosquitoes (Tokyo University Press, 1993), in Japanese.

  • J.C. Jones, Scientific American 238, 112–120 (1978).

    Article  Google Scholar 

  • H. Kawahara, S. Ochi, K. Tanetani, K. Kato, M. Isogai, Y. Mizuno, H. Yamamoto, and A. Yamagami, Shika Rikogaku Zasshi 4(6), 65–85 (1963).

    Google Scholar 

  • S. Kurihara, T. Kurita, and S. Katayama, J. New Rem. & Clin. 52(2), 104–112 (2003), in Japanese.

    Google Scholar 

  • F.J. Martin and C. Grove, Biomedelical Micodevices 3(2), 97–108 (2001).

    Google Scholar 

  • A. Oki, M. Takai, H. Ogawa, Y. Takamura, T. Fukasawa, J. Kikuchi, Y. Ito, T. Ichiki, and Y. Horiike, Jpn. J. Appl. Phys. 42, 3722–3727 (2003).

    Article  Google Scholar 

  • Y. Okazaki, Y. Ito, A. Ito, and T. Tateishi, Annual Report of Mechanical Engineering Laboratory 46(5) 397–416 (1992), in Japanese.

    Google Scholar 

  • Piezo-ceramic, Technical handbook, Fuji Ceramics Corporation.

  • L.M. Schetky, Scientific American 241–245, 68–76 (1979).

    Google Scholar 

  • M. Tabib-Azar, Microactuators (Kluwer Academic Publishers, 1998).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kazuyoshi Tsuchiya.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tsuchiya, K., Nakanishi, N., Uetsuji, Y. et al. Development of Blood Extraction System for Health Monitoring System. Biomed Microdevices 7, 347–353 (2005). https://doi.org/10.1007/s10544-005-6077-8

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10544-005-6077-8

Keywords

Navigation