Abstract
We developed a scintillating fiber-optic image sensor system (SFISS) using square plastic optical fibers (POFs), a scintillating film, a right-angle mirror, and a complementary metal-oxide semiconductor (CMOS) image camera for dosimetry in radiotherapeutic applications. In this study, the scintillating light images were obtained for measuring two-dimensional planar dose distributions of a 6MV photon beam in a solid-water phantom. We also measured the percentage depth doses (PDDs) of 6 and 15MV photon beams using the SFISS and compared them with those obtained using conventional dosimetry films. The proposed sensor has many advantages, such as real-time readout, high-resolution measurement, and lack of corrections for temperature, pressure, and humidity. From the results of this study, it is expected that a SFISS can be developed to accurately measure the dose distribution in a small beam field for stereotactic radiosurgery (SRS).
Similar content being viewed by others
References
D. Létourneau, J. Pouliot, and R. Roy: Med. Phys. 26 (1999) 2555.
R. K. Rice, J. L. Hansen, G. K. Svensson, and R. L. Siddon: Phys. Med. Biol. 32 (1987) 1087.
J.-S. Tsai, G. K. Svensson, and B. E. Bjarngard: Phys. Med. Biol. 33 (1988) 119.
A. S. Beddar, D. L. Mason, and P. F. O’Brien: Med. Phys. 21 (1994) 1075.
A. S. Beddar: Radiat. Meas. 41 (2006) S124.
Task Group 21: Med. Phys. 10 (1983) 741.
T. Aoyama, S. Koyama, and H. Maekoshi: Proc. 6th Int. Conf. Medical Physics, 1999, p. 117.
M. Westermark, J. Arndt, B. Nilsson, and A. Brahme: Phys. Med. Biol. 45 (2000) 685.
C. F. Chuang, L. J. Verhey, and P. Xia: Med. Phys. 29 (2002) 1109.
D. A. Low, K. S. Chao, S. Mutic, R. L. Gerber, C. A. Perez, and J. A. Purdy: Int. J. Radiat. Oncol. Biol. Phys. 42 (1998) 681.
M. A. Clift, R. A. Sutton, and D. V. Webb: Phys. Med. Biol. 45 (2000) 1885.
L. Archambault, A. S. Beddar, L. Gingras, F. Lacroix, R. Roy, and L. Beaulieu: Med. Phys. 34 (2007) 1583.
M. P. Petric, J. L. Robar, and B. G. Clark: Med. Phys. 33 (2006) 96.
W. U. Laub, T. W. Kaulich, and F. Nusslin: Phys. Med. Biol. 44 (1999) 2183.
J. M. Fontbonne, G. Iltis, G. Ban, A. Battala, J. C. Vernhes, J. Tillier, N. Bellaize, C. Le Brun, B. Tamain, K. Mercier, and J. C. Motin: IEEE Trans. Nucl. Sci. 49 (2002) 2223.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Shin, S.H., Yoo, W.J., Seo, J.K. et al. Measurements of planar and depth dose distributions using a scintillating fiber-optic image sensor system for dosimetry in radiotherapeutic applications. OPT REV 20, 178–181 (2013). https://doi.org/10.1007/s10043-013-0029-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10043-013-0029-y