Skip to main content
Log in

Identification of noise sources in scroll compressor for air-conditioner

  • Materials & Fracture · Solids & Structures · Dynamics & Control · Production & Design
  • Published:
KSME International Journal Aims and scope Submit manuscript

Abstract

Low noise of air-conditioners is one of the most important issues because of the users’ strong demand. The main source of noise in an air-conditioner is the compressor. Therefore, noise reduction in a compressor is quite significant as an element technology in the air-conditioner field. Recently, scroll compressors are widely used, because they feature low noise, due to less pulsation of gas pressure, than that of rotary compressors. For reduction of noise, the source of noise must be identified. This paper presents a detailed analysis to identify the noise source and shows the dominant factors of noise of the scroll compressor, which will make it possible to design a scroll compressor with low noise.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bush, J. W., Eyo, V. A. and Housman M. E., 1996. “Design Techniques and Resulting Structural Modifications used to Reduce Hermetic Compressor Noise,”Int. Comp. Eng. Conf. at Purdue, pp. 967–975.

  • Iwata, H., Nakamura, M. and Matsusita, O., Sutou, M., 1990. “Vibration and Noise reduction of Compressors for Air-Conditioner,”Trans. of the JSRAE, Vol. 7, No. 2, pp. 1–13.

    Google Scholar 

  • Motegi, S. Nakashima, S., 1996. “A Study on Noise Reduction in a Scroll Compressor,”Int. Comp. Eng. Conf. at Purdue, pp. 605–610.

  • Sano, K., Kawahara, S. and Akazawa, T., Ishii, N., 1997. “Experiment Study for Reduction of Noise and Vibration in Hermetic Compressor (1st Report: Reduction of Noise caused by Resonance of each Scroll compressor Element,”Trans. of the JSRAE, Vol. 14, No. 2, pp. 125–136.

    Google Scholar 

  • Sano, K., Kawahara, S. and Akazawa, T., Ishii, N., 1997. “Experiment Study for Reduction of Noise and Vibrations in Hermetic Compressor (2nd Report: Noise due to Cavity Resonance in various Compressor Spaces),”Trans. of the JSRAE, Vol. 14, No. 2, pp. 137–148.

    Google Scholar 

  • Sano, K., Kawahara, S. and Akazawa, T., Ishii, N., 1997. “Experiment Study for Reduction of Noise and Vibrations in Hermetic Compressor (3rd Report: Electro-magnetic Noise for Inverter Driven Compressors),”Trans. of the JSRAE, Vol. 14, No. 2, pp. 149–158.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jin-Kab Lee.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lee, JK. Identification of noise sources in scroll compressor for air-conditioner. KSME International Journal 14, 597–604 (2000). https://doi.org/10.1007/BF03184436

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03184436

Key Words

Navigation