Synopsis
The paper presents data on the performance on a range of raw waters of an electrodialysis reversal plant operated at a large coal fired power station in the North Eastern Region of the Central Electricity Generating Board. The performance of the system in terms of salt rejection and output is assessed and its potential role for the production of boiler feed water make-up briefly discussed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1987 Elsevier Applied Science Publishers Ltd
About this chapter
Cite this chapter
Fitchett, G.A. (1987). Experience Within the CEGB of the Electrodialysis Reversal Technique for the Production of Boiler Feed Water Make-Up. In: Williams, P.A., Hudson, M.J. (eds) Recent Developments in Ion Exchange. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-3449-8_13
Download citation
DOI: https://doi.org/10.1007/978-94-009-3449-8_13
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-8044-6
Online ISBN: 978-94-009-3449-8
eBook Packages: Springer Book Archive