Abstract
A coil heat exchanger for hot water thermal storage was presented including the choice of the design parameters, thermal calculation, structural design and calculation of flow resistance. In this design, solar collector contour aperture area is 4.26 m2, the volume of water tank is 300L. The diameter and the coil heat transfer area of spiral coil heat exchanger are 460 mm and 1.48m2, respectively, which was made of φ 15 mmx1 mm stainless steel tube, the total length of the coil is 31.8m. The calculation results showed that the thermal design fits the requirements of the hot water system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Tsinghua University Press, Beijing and Springer-Verlag GmbH Berlin Heidelberg
About this paper
Cite this paper
Cuiping, L., Duanlian, H., Jianqing, D. (2008). Design of Coil Heat Exchanger for Remote-Storage Solar Water Heating System. In: Goswami, D.Y., Zhao, Y. (eds) Proceedings of ISES World Congress 2007 (Vol. I – Vol. V). Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-75997-3_432