Frequency characteristics of the electrical conductivity in normal and coagulated blood

  • Conference paper

Part of the book series: IFMBE Proceedings ((IFMBE,volume 17))

Abstract

The electrical conductivity and phase shift of normal and coagulated blood sampled from 10 pigs were measured using an LCR meter, Agilent 4285A. The hematocrit of normal blood was also measured. The conductivity difference between normal and coagulated blood remained at 4.3 mS/cm up to 800 kHz, and then gradually decreased. The conductivity difference was not correlated with the hematocrit (correlation coefficient = 0.04). The phase difference between normal and coagulated blood reached the maximum, -13.5 degree, between 1 and 2 MHz. Therefore, it is possible to discriminate thrombi from air emboli using the phase difference at the frequency range of 1 to 2 MHz.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Nebuya S, Brown BH et al. (1999) Measurement of high frequency electrical transfer impedances from biological tissues. Electron Let 35-23:1–2

    Google Scholar 

  2. Nebuya S, Noshiro M et al. (2004) Estimation of the size of air emboli detectable by electrical impedance measurement. Med & Biol Eng & Comput 42:142-144

    Article  Google Scholar 

  3. Nebuya S, Noshiro M et al. (2006) Detection of emboli in vessels using electrical impedance measurements – phantom and electrodes. Physiol Meas 26:S111-S118

    Article  Google Scholar 

  4. Geselowitz DB (1971) An application of electrocardiographic lead theory to impedance plethysmography. IEEE Trans Bio-med Eng 18:38-41

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Noshiro, M., Nebuya, S., Fujimaki, A., Smallwood, R., Brown, B. (2007). Frequency characteristics of the electrical conductivity in normal and coagulated blood. In: Scharfetter, H., Merwa, R. (eds) 13th International Conference on Electrical Bioimpedance and the 8th Conference on Electrical Impedance Tomography. IFMBE Proceedings, vol 17. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-73841-1_21

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-73841-1_21

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-73840-4

  • Online ISBN: 978-3-540-73841-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics